Spiral
®
SST and STT Prewire Installation Manual
Spiral
®
SST and STT Prewire Installation Manual
■
1072124-0
■
Rev 03
■
01/22
12
12
Plumb
the side columns to each other.
13
If necessary, shim
the side columns so they are plumb to each other.
Laser level
Measuring
tape
Measure
distance
from front of each
column to laser line.
Distances
must match.
Shims
Step 2: Install the rear seal
1
Install
bolts on both sides of the seal and
hand tighten.
2
Make sure
the back of the seal is flush with the back of the side
column and that there is direct contact with the wall.
▪
If necessary,
shim the seal
where it meets both side columns and at the
anchor point so that both conditions are met.
3
Make sure
the rear seal is level.
Anchor
rear seal to wall
at all anchor points.
4
10mm
Tighten
the bolts on both sides of the seal.
SMALL PARTS
0550259-0Z01
Drive
side
Non-
drive
side
4
10mm
Hand tight
Shims
Spirit level
Anchoring
hardware
Check level
Anchor point