manualshive.com logo in svg
background image

3 — English

GENERAL SAFETY RULES

SPECIFIC SAFETY RULES

 

Know your inflator. 

Read operator’s manual carefully. 

Learn its applications and limitations, as well as the spe-
cific potential hazards related to this tool. Following this 
rule will reduce the risk of electric shock, fire, or serious 
injury.

 

Risk of bursting. 

Do not operate inflator to result in out-

put pressure greater than marked maximum pressure of 
item to be inflated. Do not use at pressure greater than 
150 PSI.

 

To reduce the risk of electric shock,

 do not expose to 

rain. Store indoors.

 

Inspect unit for cracks, pin holes, or other imperfec-
tions that could cause inflator to become unsafe. 

Never cut or drill holes in the inflator.

 

Make sure the hose is free of obstructions or snags.

 

Entangled or snarled hoses can cause loss of balance or 
footing and may become damaged.

 

Use the inflator only for its intended use. Do not alter 
or modify the unit from the original design or function.

 

Always be aware that misuse and improper handling 

of this inflator can cause injury to yourself and others.

 

Never  leave  an  inflator  unattended  with  the  nozzle 

attached to the item being inflated.

 

Do not continue to use a inflator or nozzle that leaks 

air or does not function properly.

 

Always disconnect the battery pack before making 
adjustments, servicing an inflator, or when an inflator 
is not in use.

 

Do not attempt to pull or carry the inflator by the 
hoses.

 

Always follow all safety rules recommended by the 

manufacturer of your inflator, in addition to all safety 
rules for the inflator. 

Following this rule will reduce the 

risk of serious personal injury.

 

Household use only.

 

Do not use inflator as a breathing device.

 

Never direct a jet of compressed air toward people or 

animals. Take care not to blow dust and dirt towards 
yourself or others. 

Following this rule will reduce the risk 

of serious injury.

 

Protect your lungs. 

Wear a face or dust mask if the op-

eration is dusty. Following this rule will reduce the risk of 
serious personal injury.

 

Do not use this inflator to spray chemicals. 

Your lungs 

can be damaged by inhaling toxic fumes.

 

Check damaged parts. Before further use of the infla-
tor or air tool, a guard or other part that is damaged 
should be carefully checked to determine that it will 
operate properly and perform its intended function.

 

Check for alignment of moving parts, binding of mov-
ing parts, breakage of parts, mounting, and any other 
conditions that may affect its operation. A guard or 
other part that is damaged should be properly repaired 

or replaced by an authorized service center. 

Follow-

ing this rule will reduce the risk of shock, fire, or serious 
injury.

 

Risk of bursting. 

Carefully monitor objects during 

 inflation.

 

To reduce the risk of over inflation, 

use a reliable pres-

sure gauge periodically during inflation.

 

Never leave the inflator unattended during inflation.

 

Never block the inflating or deflating outlets while 
operating.

 

Do not use a battery pack that is damaged or modified. 

Damaged or modified batteries may exhibit unpredictable 
behavior resulting in fire, explosion or risk of injury.

 

Do not modify or attempt to repair a battery pack that 
has been damaged.

 

Do not expose a battery pack or appliance to fire or 
excessive temperature. 

Exposure to fire or temperature 

above 265°F may cause explosion. 

 

Follow all charging instructions and do not charge the 
battery pack or appliance outside of the temperature 
range specified in the instructions. 

Charging improperly 

or at temperatures outside of the specified range may 
damage the battery and increase the risk of fire.

 

Have servicing performed by a qualified repair person 
using only identical replacement parts. 

This will ensure 

that the safety of the product is maintained.

 

Allow pump to cool 

for five (5) minutes after each five 

(5) minutes of continuous use. Never block the inflating 
or deflating outlets while operating.

  

Save these instructions. 

Refer to them frequently and 

use them to instruct others who may use this inflator. If 
you loan someone this inflator, loan them these instruc-
tions also.

SERVICE

 

Inflator service must be performed only by qualified 
repair personnel. 

Service or maintenance performed by 

unqualified personnel may result in a risk of injury.

 

When servicing an inflator, use only identical replace-
ment parts. Follow instructions in the Maintenance 
section of this manual.

 Use of unauthorized parts or 

failure to follow Maintenance Instructions may create a 
risk of shock or injury.

Содержание P747

Страница 1: ...e NDICE DE CONTENIDO Reglas de seguridad generales 2 3 Reglas de seguridad spec ficas 3 4 S mbolos 5 Caracter sticas 6 Armado 6 Funcionamiento 6 9 Mantenimiento 9 Ilustraciones 10 12 Pedidos de piezas...

Страница 2: ...ate inflator near flammable liquids or in gaseous or explosive atmospheres Internal sparks may ignite fumes Do not store your inflator in a damp or wet location Do not store in locations where the tem...

Страница 3: ...use of the infla tor or air tool a guard or other part that is damaged should be carefully checked to determine that it will operate properly and perform its intended function Check for alignment of m...

Страница 4: ...may prohibit disposal of batteries in ordinary trash Consult your local waste authority for information regarding avail able recycling and or disposal options Hot Surface To reduce the risk of injury...

Страница 5: ...ct that is not properly and completely assembled or with damaged or missing parts could result in serious personal injury WARNING Do not attempt to modify this product or create acces sories or attach...

Страница 6: ...auge and monitoring the amount of pressure being applied to the item being inflated Pressure is indicated by PSI Press the mode power button to turn on the digital gauge The unit will start up in high...

Страница 7: ...curate reading stop inflating and follow above instructions for reading the air pressure NOTE Stand 10 feet away from item during inflation Turn off the inflator and store the hose in the hose wrap on...

Страница 8: ...7 1 Failure to do so could result in objects being thrown into your eyes resulting in possible serious injury NOTE ILLUSTRATIONS START ON PAGE 10 AFTER FRENCH AND SPANISH LANGUAGE SECTIONS OPERATION I...

Страница 9: ...n cas de situation impr vue Utiliser l quipement de s curit Toujours porter une protection oculaire Suivant les conditions le port d un masque filtrant de chaussures de s curit d un casque ou d une pr...

Страница 10: ...lles d origine pour les r parations Se conformer aux instructions de la section Entretien de ce manuel L utilisation de pi ces non autoris es ou le non respect des instructions peut pr senter des risq...

Страница 11: ...que d clatement Surveiller les objets pendant l inflation Pour r duire les risques de mani re excessive utiliser un manom tre talon r guli rement pendant l inflation Ne jamais laisser un gonfleur en f...

Страница 12: ...ernementalespeuventinterdiredejeterlespilesdans lesorduresm nag res Consulterlesautorit slocalescomp tentes pour les options de recyclage et ou l limination Surface br lante Pour viter les risques de...

Страница 13: ...s pneus gonfl s au moyen de cet appareil Conduire un v hicule avec des pneus mal gonfl s peut entra ner des blessures graves AVIS L accessoire de gonflage n est pas con u pour une application continue...

Страница 14: ...m tre num rique est actif pendant environ cinq minutes Pour teindremanuellement appuyeretmaintenirle bouton Mode enfonc jusqu ce que le t moin s teigne puis rel cher le bouton MANOM TRE NUM RIQUE Voir...

Страница 15: ...se Appuyer sur le bouton de mode alimentation pour mettre le manom tre num rique en marche L appareil se lancera pas d faut en mode de haute pression NOTE Veiller ce que le manom tre num rique soit r...

Страница 16: ...desserrer l crou de blocage sur la rige de la valve pour gonfler Une fois le gonflage termin serrer l crou de blocage pour fermer la valve du pneu Pour utiliser l adaptateur de valve Presta Enfiler l...

Страница 17: ...de seguridad Siempre p ngase protecci n ocular Cuando lo exijan las circunstancias debe ponerse careta contra el polvo zapatos de seguridad antiderrapantes casco o protecci n auditiva Se requiere prot...

Страница 18: ...e el manual del operador Aprenda sus usos y limitaciones as como los posibles peligros espec ficos de esta herramienta Con el cumplimiento de esta regla se reduce el riesgo de una descarga el ctrica i...

Страница 19: ...esinflado mientras opere la m quina No utilice un paquete de bater as que est da ado o modificado Las bater as da adas o modificadas pueden tener un funcionamiento impredecible que provoque incendios...

Страница 20: ...ofederalesproh bandesechar las bater as en la basura normal Consulte a las autoridades reguladoras de desechos para obtener informaci n en relaci n con las alternativas de reciclado y desecho disponib...

Страница 21: ...bater as se evita arrancar accidentalmente la unidad lo cual puede causar lesiones serias ADVERTENCIA Siempre p ngase protecci n ocular con protecci n lateral con la marca de cumplimiento de la norma...

Страница 22: ...ad Para apagarla mantenga presionado el bot n de modo encendido hasta que se apague la luz luego suelte el bot n APAGADO AUTOM TICO Elmedidordigitalpermanecer encendidoduranteunm ximo de cinco minutos...

Страница 23: ...fle soplando en su interior La Aguja pelota deportivo puede usarse para infla cualquier tipo de bal n deportivo o cualquier art culo que requiera una Aguja pelota deportivo de inflado Alinee las ranur...

Страница 24: ...ulaPresta sueltelacontratuerca del v stago de v lvula para poder inflar Una vez inflado apriete la contratuerca para cerrar la v lvula del neum tico Para usar el adaptador de v lvula Presta Rosque el...

Страница 25: ...mangueras G Accessory storage rangement des accessoires almacenamiento de accesorios H Inflator port port de gonflage puerto de inflado I Deflator port port de d gonflage puerto de desinflado J Pin g...

Страница 26: ...de valve v stago de v lvula B Air chuck attache de mandrin pneumatique plato neum tico C Air hose flexible pneumatique manguera de aire A B C A A Deflator port port de d gonflage puerto de desinflado...

Страница 27: ...resta A C D B Fig 10 A Air chuck attache de mandrin pneumatique plato neum tico B Tapered adaptor adaptateur effil bot n de adaptador c nico C Presta valve adaptor adaptateur de valve Presta adaptador...

Страница 28: ...___________ SERIAL NUMBER ____________________________ Pour faire une demande de r parations ou obtenir des pi ces de rechange trouver un Centre de r parations agr pour obtenir un soutien technique ou...

Отзывы: