Indicator
Status
Meaning
Link
Solid on
The upper link has been established.
Off
Failed to establish the upper link.
RDY
On
Initialization completed.
Off
Initialization failed.
Features
The following table describes the basic features:
Table 1-33 Specifications of the SIC-1CE1 Card
Number of Ports
One
Interface Type
DB9 female connector
Cables
Balanced cables or non-balanced cables
Standard Compliance
ITU-T G.703
Operating Temperature:
Operating temperature: 0°C to 45°C
Storage temperature: -40°C to 70°C
Humidity
Operating humidity: 10%–90% RH
EMC
EMI: GB 9254-2008 Class A
EMS: GB/T 17618-1998
Cables
The following types of cables are provided:
Balanced cable with the RJ-45 plug: One end is the DB9 male connector, and the other end is the RJ-45 plug. The
characteristic impedance of the cable is 120Ω.
Balanced cable with the RJ-45 jack: One end is the DB9 male connector, and the other end is the RJ-45 jack. The
characteristic impedance of the cable is 120Ω.
Non-balanced cable: One end is the DB9 male connector, and the other end is attached with two male BNC connectors.
The characteristic impedance of the cable is 75Ω.
The cables are customer supplied.
SIC-SEC
SIC card model: SIC-SEC
Image and Indicators
The following figure shows the image of a Ruijie IPSec SIC with the key encryption function.
Figure 1-37 SIC-SEC