Note: The figure is only for reference, and the specific object prevails.
Mounting on the Workbench
In actual application, the standard 19-inch cabinet may be unavailable. In this case, the router is often mounted on a clean
workbench. The operation is easy and the requirements are as follows:
The workbench is stable and is properly grounded.
The supplied plastic cushion is stuck to the small hole at the bottom of the router and a space of 10 cm is set aside
around the router for dissipation.
No weight is placed on the top of the router.
Installing the Power Cable and the Grounding Cable
Ruijie RSR20-14E series routers support the following AC power supply:
AC: 100–240 VAC; 50 Hz to 60 Hz;
Verify that the power supply meets the requirement.
The router power cable is composed of three wires. You are recommended use a single-phase power socket with a
natural connector or a multifunctional PC power socket. The neutral point of the power supply should be reliably grounded
in the building. For common buildings, the neutral points have been buried into the ground during construction and wiring.
You must verify if the power supply of the building has been properly grounded.
The following table describes the procedure for installing the power cable: