The following table describes panel indicators.
Table 1-34 LED Indicator on the SIC-SEC Card
Indicator
Status
Meaning
RDY
On
Initialization completed.
Off
Initialization failed.
Features
The following table describes the basic features:
Table 1-35 Specifications of the SIC-SEC Card
Number of Ports
None
Interface Type.
N/A
Cables
N/A
Function Description
The module encrypts keys and enables the encryption algorithm.
Operating Temperature
Operating temperature: 0°C to 50°C
Storage temperature: -40°C to 70°C
Humidity
Operating humidity: 10% to 95% RH (non condensing)
EMC
EMI: GB 9254-2008 ClassA
EMS: GB/T 17618-1998
Cables
The cables are not supplied with the router.
SIC-3G-TD Interface Card
SIC card model: SIC-3G-TD
Image and Indicator
The following figure shows the image of an SIC-3G-TD interface card.
Figure 1-38 SIC-3G-TD