Indicator
Status
Meaning
RDY
On
Initialization completed.
Off
Initialization failed.
B1
On
B1 channel is active.
Off
B1 channel is idle.
B2
On
B2 channel is active.
Off
B2 channel is idle.
Features
The following table describes the basic features:
Table 1-19 Specifications of the SIC-1B-U Card
Number of Ports
One
Interface Type
RJ-45 port (compatible with RJ-11)
Cables
Telephone cable
Standard Compliance
ITU-T I.430,Q.921,Q.931
Temperature:
Operating temperature: 0°C to 45°C
Storage temperature: -40°C to 70°C
Humidity
Operating humidity: 10% to 90% RH
EMC
EMI: GB 9254-2008 Class A
EMS: GB/T 17618-1998
Table 1-20 Specifications of the SIC-1B-S/T Card
Number of Ports
One
Interface Type
RJ-45
Cables
ISDN S/T cables
Terminal Resistance
Built-
in 100Ω
Standard compliance
ITU-T I.430,Q.921,Q.931
Operating Temperature:
Operating temperature: 0°C to 45°C
Storage temperature: -40°C to 70°C
Humidity
Operating humidity: 10% to 90% RH
EMC
EMI: GB 9254-2008 Class A
EMS: GB/T 17618-1998
Cables
The SIC-1B-U module uses standard telephone cables.
The SIC-1B-S/T module uses standard ISDN S/T cables or RJ-45 to R-J45 straight-through cables.
The cables are customer supplied.