Страница 1: ...RG RSR20 14E Series Routers Hardware Installation and Reference Guide 1 20 ...

Страница 2: ...tten consent of Ruijie Networks is prohibited are registered trademarks of Ruijie Networks Counterfeit is strictly prohibited Exemption statement This document is provided as is The contents of this document are subject to change without any notice Please obtain the latest information through the Ruijie Networks website Ruijie Networks endeavors to ensure content accuracy and will not shoulder any...

Страница 3: ... Customer service center http www ruijie com cn service aspx Customer services hotline 86 4008 111 000 BBS http support ruijie com cn Customer services email service ruijie com cn Related Documents Documents Description Configuration Guide Describes network protocols and related mechanisms that supported by the product with configuration examples Command Reference Describes the related configurati...

Страница 4: ...This symbol means that you must be extremely careful not to do some things that may damage the device or cause data loss ...

Страница 5: ...tton to upgrade the RGOS operating system in the SD card or USB storage device into the device and IP multicast protocols and provides rich QoS features offering a three network in one solution for medium small sized enterprises The RSR20 14E modular router supports up to four optional Smart Interface Cards SIC Different SIC slots support different SIC cards For your convenience each slot is marke...

Страница 6: ...S 4 SIC 1CE1 4 This module supports up to 64 channels For your convenience each slot is marked with the supported SIC types For example in Figure 1 1 SIC SLOT 4 supports Type A Type B Type C and Type D SIC cards Figure 1 1 SIC Types Marked Above the SIC SLOT 4 on RSR20 14E V1 0 Figure 1 2 Part of Back Panel of the RSR20 14E V1 0 Figure 1 3 SIC Types Marked Above the SIC SLOT 5 on RSR20 14E V1 2 In...

Страница 7: ...ty 10 to 95 RH Product Features Access density and processing capability Each SIC slot respectively supports up to four non channelized E1 four ISDN U or S T interfaces four sync serial interfaces 32 asyn serial interfaces to provide the high density remote OA solution 24 Layer 3 switching Ethernet interfaces 2 Gigabit Ethernet interfaces and 2SFP ports fiber copper combo ports the SFP can be comp...

Страница 8: ...lding the router is highly resistant to shock high low temperature and electromagnetic radiation and works stably Certificate The router has passed the network access license NAL testing by the Ministry of Information Industry MII P R China Product Image and LED Indicators Front Panel Figure 1 5 Front panel of RSR20 14E Router Note 1 FE 1 0 port 2 FE1 23 port 3 GE 0 0 and GE 0 1 ports 4 GE and SFP...

Страница 9: ...e USB device is connected to the system and is recognized Blinking green The USB device is exchanging data with the host device Off The USB device is not connected or is not working properly SD Solid green The SD card is connected to the system and is recognized Blinking green The SD card is exchanging data with the host device Solid or blinking red The SD card is not working properly Back Panel F...

Страница 10: ...fications of the AUX port Index Parameter Interface Standard EIA TIA RS232 Connector RJ 45 Rate Supports 9600 19200 38400 57600 and 115200 bps baud rates The default is 9600 bps Cables Serial cables are supplied with the RSR20 14E series router FE Ports Port Image and LED Indicators Figure1 7 Appearance of the 24FE port For descriptions of FE port Link ACT LED indicators see the LED Indicators sec...

Страница 11: ...d respectively The crossover cable is used to connect two terminal devices such as connecting a PC to a PC and connecting a router to a router If the port supports Auto MDI MDIX both straight through and crossover cables can be used Considering that you may customize cables the following section describes how to wire straight through and crossover cables As shown in the following figure the pins o...

Страница 12: ...ing Link ACT LED indicators Figure1 11 GE and SFP Ports and Corresponding LED Indicators For descriptions of GE and SFP port Link ACT LED indicators see the LED Indicators section Features The RSR20 14E series router provides two 10 100 1000 Mbps Ethernet ports The GE0 0 and the SFP0 are a combo port and the GE0 1 and the SFP1 are also a combo port The copper port uses an RJ 45 connector while the...

Страница 13: ...espond to pin 3 and pin 6 at the other end respectively The crossover cable is used to connect two terminal devices such as connecting a PC to a PC and connecting a router to a router If the port supports Auto MDI MDIX both straight through and crossover cables can be used Considering that you may customize cables the following section describes how to wire straight through and crossover cables As...

Страница 14: ...BASE LH mini GBIC transceiver LC 40 km Mini GBIC ZX50 1 port 1000BASE ZX mini GBIC transceiver LC 50 km Mini GBIC ZX80 1 port 1000BASE ZX mini GBIC transceiver LC 80 km The optional transmission media are as followings Table 1 13 Optional Transmission Media and Transmission Distances Media Wavelength Fiber Maximum Transmission Distance 100BASE FX 1310 nm 9 125 um single mode optical fiber 2 km 15 ...

Страница 15: ...strictly follow the Configuring Reliability chapter in the related software configuration guide For the avoidance of system abnormality hot swapping is not allowed unless the command for unplugging the USB is entered The USB device here refers to USB flash disks Cables If you connect a USB device with a USB extension cable the cable must be less than 5 meters SD Card Slot LED Indicator For descrip...

Страница 16: ...e SD card is entered Cables Ruijie Networks SDCH card Kingston 4GB class_4 FUNC Button FUNC Button Image Figure 1 15 FUNC Button The FUNC button is close to the SD card slot on the front panel It is used for one button upgrade To avoid careless touching the button is designed to be pressed using a tiny needle Features One button upgrade is the process that users press the FUNC button on the device...

Страница 17: ... storage medium is inserted the system scans for an SD card first If no SD card is inserted or the inserted SD card does not contain applicable installation packages or configuration files the system scans for a USB flash drive If neither the inserted SD card nor the USB flash drive contains applicable installation packages or configuration files the software versions and configuration files are n...

Страница 18: ...192000 bps Indicator There are two LED indicators One LED indicating the LINK status of one port which turns on when the physical link is set up and the upper layer protocol is up One LED indicating the RDY status of one link card which turns on when the motherboard detects the module Interface DB26 Environmental Operating temperature 0 C to 45 C Operating humidity 10 to 90 RH Storage temperature ...

Страница 19: ...d of this cable is the DB34 male connector and the other end is the DB26 male connector Figure 1 19 V 35 DTE cable V 35 DCE One end of this cable is the DB34 female connector and the other end is the DB26 male connector Figure 1 20 V 35 DCE cable V 35 DTE V 35 DCE Both ends of this cable are DB26 male connectors Figure1 21 V 35 DTE V 35 DCE cable ...

Страница 20: ...d SIC 1B U Figure 1 22 ISDN 1B U The SIC 1B U is a Type A SIC which can be inserted in a slot marked with A The following figure shows the image of the 1 port ISDN S T U interface card SIC 1B S T Figure 1 23 SIC 1B S T The SIC 1B S T is a Type A SIC which can be inserted in a slot marked with A Each card has a port working status ACT indicator and the card Ready indicator Besides each ISDN card ha...

Страница 21: ...orage temperature 40 C to 70 C Humidity Operating humidity 10 to 90 RH EMC EMI GB 9254 2008 Class A EMS GB T 17618 1998 Table 1 20 Specifications of the SIC 1B S T Card Number of Ports One Interface Type RJ 45 Cables ISDN S T cables Terminal Resistance Built in 100Ω Standard compliance ITU T I 430 Q 921 Q 931 Operating Temperature Operating temperature 0 C to 45 C Storage temperature 40 C to 70 C ...

Страница 22: ...n established Off Failed to establish the upper link RDY On Initialization completed Off Initialization failed Features The following table describes the basic features Table 1 22 Specifications of the SIC 1E1 F Card Number of Ports One Interface Type DB9 female connector Cables Balanced cables or non balanced cables Standard Compliance ITU T G 703 Operating Temperature Operating temperature 0 C t...

Страница 23: ...e 1 23 Signals of the DB9 Male to RJ 45 Plug Cable DB9M RJ 45 Plug Signal 1 5 RX Ring 2 4 RX Tip 4 1 TX Tip 5 2 TX Ring Balanced cable with the RJ 45 jack One end is the DB9 male connector and the other end is the RJ 45 jack The characteristic impedance of the cable is 120Ω Figure 1 26 Balanced cable with the RJ 45 jack Considering that you may customize cables the following section describes conn...

Страница 24: ...nchronous interface card Figure 1 28 SIC 8A The SIC 8A is a Type A SIC which can be inserted in a slot marked with A The interface card includes one SCSI DB68 connector and eight asynchronous interfaces It includes one RDY indicator and eight ACT indicators The following table describes panel indicators Table 1 25 LED Indicators on the SIC 8A Card Indicator Status Meaning ACT Blinking Data is bein...

Страница 25: ... 2008Class A EMS GB T 17618 1998 Cables The following cables are provided Asynchronous cable with1 DB68 male connector to 8 RJ 45 plugs Asynchronous cable with 1DB68 male connector to 8 RJ 45 jacks The following three types of converters are provided RJ 45 jack to DB25 female connector converter RJ 45 jack to DB25 male connector converter RJ 45 jack to DB9 female connector converter Asynchronous c...

Страница 26: ...n of the RJ 45 plug or the RJ 45 female socket attached by the converter cable is for the routers Asynchronous cable with 1 DB68 male connector to 8 RJ 45 jacks One end is a DB68 male connector and the other end is attached with eight RJ 45 jacks Figure 1 30 Asynchronous Cable with 1 DB68 Male Connector to 8 RJ 45 Jacks For the cable pinout please see Table 1 24 RJ 45 jack to DB25 female connector...

Страница 27: ...ard model SIC 2FXS Image and Indicators The following figure shows the image of an SIC 2FXS interface card Figure 1 34 SIC 2FXS The SIC 2FXS is a Type A SIC which can be inserted in a slot marked with A The interface card includes the IN USE indicators for ports and one RDY indicator The following table describes panel indicators Table 1 28 LED Indictors on the SIC 2FXS Card Indicator Status Meani...

Страница 28: ...rature 40 C to 70 C Humidity Operating humidity 10 to 90 RH EMC EMI GB 9254 2008 Class A EMS GB T 17618 1998 Cables The SIC 2FXS interface module uses standard phone cables The cables are customer supplied SIC 2FXO Interface Card SIC card model SIC 2FXO Image and Indicators The following figure shows the image of an SIC 2FXO interface card Figure 1 35 SIC 2FXO The SIC 2FXO is a Type A SIC which ca...

Страница 29: ...erating Temperature Operating temperature 0 C to 45 C Storage temperature 40 C to 70 C Humidity Operating humidity 10 to 90 RH EMC EMI GB 9254 2008 Class A EMS GB T 17618 1998 Cables The SIC 2FXO module uses standard phone cables The cables are customer supplied SIC 1CE1 Interface Card SIC card model SIC 1CE1 Image and Indicators The following figure shows the image of a 1 port channelized E1 card...

Страница 30: ...4 2008 Class A EMS GB T 17618 1998 Cables The following types of cables are provided Balanced cable with the RJ 45 plug One end is the DB9 male connector and the other end is the RJ 45 plug The characteristic impedance of the cable is 120Ω Balanced cable with the RJ 45 jack One end is the DB9 male connector and the other end is the RJ 45 jack The characteristic impedance of the cable is 120Ω Non b...

Страница 31: ...ce Type N A Cables N A Function Description The module encrypts keys and enables the encryption algorithm Operating Temperature Operating temperature 0 C to 50 C Storage temperature 40 C to 70 C Humidity Operating humidity 10 to 95 RH non condensing EMC EMI GB 9254 2008 ClassA EMS GB T 17618 1998 Cables The cables are not supplied with the router SIC 3G TD Interface Card SIC card model SIC 3G TD I...

Страница 32: ...e RDY On Initialization completed Off Initialization failed Features The following table describes the basic features Table 1 37 Specification of the SIC 3G TD Card Number of Ports One Interface Type RJ 45 Cables Serial cables Rate HSDPA downlink 2 8 Mbps uplink 384 Kbps EDGE downlink 236 8 Kbps uplink 236 8 Kbps TD SCDMA downlink 384 Kbps uplink 384 Kbps GPRS downlink 85 6 Kbps uplink 85 6 Kbps O...

Страница 33: ...weak or not present EV DO Solid green Effective EV DO service Off No EV DO service RTT Solid green Effective RTT service Off No RTT service RDY On Initialization completed Off Initialization failed Features The following table describes the basic features Table 1 39 Specification of the SIC 3G CDMA Card Number of Ports One Interface Type RJ 45 Cables Serial cables Rate 1x EV DO Rev A downlink 3 1 ...

Страница 34: ...olid green Link up Blinking green Data is being transmitted RSSI Solid green Strong signal Blinking green Intermediate or low signal Off Signal is weak or not present HSDPA Solid green Effective HSDPA service Off No HSDPA service UMTS Solid green Effective UMTS service Off No UMTS service RDY On Initialization completed Off Initialization failed Features The following table describes the basic fea...

Страница 35: ...igure 1 41 SIC 3G CDMA E The SIC 3G CDMA E is a Type E module which can be inserted in a slot marked with E The following table describes panel indicators Table 1 42 LED Indicators on the SIC 3G CDMA E Card Indicator Status Meaning WWAN network status Solid green Link up Blinking green Data is being transmitted RSSI Solid green Strong signal Blinking green Intermediate or low signal Off Signal is ...

Страница 36: ...umidity Operating humidity 10 to 90 RH EMC EMI GB 9254 2008 Class A EMS GB T 17618 1998 SIC 3G WCDMA E Interface Card SIC card model SIC 3G WCDMA E Image and Indicators The following figure shows the image of SIC 3G WCDMA E Figure 1 42 SIC 3G WCDMA E The SIC 3G WCDMA E is a Type E module which can be inserted in a slot marked with E The following table describes panel indicators Table 1 44 LED Ind...

Страница 37: ...Rate HSDPA downlink 7 2 Mbps uplink 5 76 Mbps UMTS downlink 384 Kbps uplink 384 Kbps EDGE downlink 236 8 Kbps uplink 236 8 Kbps GPRS downlink 85 6 Kbps uplink 85 6 Kbps Operating Temperature Operating temperature 0 C to 45 C Storage temperature 40 C to 70 C Humidity Operating humidity 10 to 90 RH EMC EMI GB 9254 2008 Class A EMS GB T 17618 1998 SIC 3G WCDMA H E Interface Card SIC model SIC 3G WCDM...

Страница 38: ...sic features Table 1 47 Specification of the SIC 3G WCDMA H E Card Number of Ports One Interface Type N A Cables N A Rate HSDPA downlink 7 2 Mbps uplink 5 76 Mbps UMTS downlink 384 Kbps uplink 384 Kbps EDGE downlink 236 8 Kbps uplink 236 8 Kbps GPRS downlink 85 6 Kbps uplink 85 6 Kbps Operating Temperature Operating temperature 0 C to 45 C Storage temperature 40 C to 70 C Humidity Operating humidi...

Страница 39: ...Point to Point Protocol over Ethernet PPPOE Supporting DNS static domain name resolution and Dynamic Domain Name Server DDNS DNS indicates Domain Name System Supporting upgrade over the asynchronous file transfer protocols of X MODEM Supporting NAT NAT PT ACL and AAA Supporting Internet Protocol Security IPSEC Layer 2 Tunneling Protocol L2TP and Point to Point Tunneling Protocol PPTP User Friendly...

Страница 40: ...rent users to run different commands on terminal ports Supporting the command alias and telnet script which can be used together with the autocommand function to directly log in to the server after pressing Enter on the terminal Supporting the fixed terminal dial up function based on different operating systems where a terminal uses the same terminal number for multiple times of login Supporting t...

Страница 41: ...tory Risk of Explosion if battery is replaced by an incorrect type Dispose or used batteries according to the instructions Installation Environment Requirements Ruijie routers are intended for indoor use For their normal operation and maximum service life they must be installed at locations that meet the following requirements Temperature and humidity requirements Cleanness requirements Anti stati...

Страница 42: ...ive humidity is low which may shorten the useful life of the device and cause communication failures The following table describes Ruijie routers requirements for the dust content and granularity in the equipment room Maximum diameter μm 0 5 1 3 5 Maximum concentration Particles m3 1 4 10 7 7 10 5 2 4 10 5 1 3 10 5 Besides the content of salts acids and sulfides in the air are also strictly limite...

Страница 43: ...tact between the grounding cable of the router and the ground Ensure that the neutral point of the AC power socket is in good contact with the ground Add a lighting arrester in front of the input of the power supply to enhance the anti lightning effect of the power supply For improve the anti lightning effect users can attach special lightning prevention equipment to the input end of outdoor signa...

Страница 44: ...de Power cable Configuration cable Ethernet cable Module interface cable The power cables and the configuration cables are provided along with Ruijie RSR20 14E series router delivery but the Ethernet cables and module interface cables are customer supplied Related devices include HUB or switch CSU DSU or other DCE device Configuration terminal that can be a terminal or a PC installed with HyperTer...

Страница 45: ...uter Follow the process to ensure a smooth installation and avoid any damage to the router Fastening the Router Fastening a router refers to the process of mounting a router to the specified location which occurs after the installation preparation is complete Routers are usually mounted In the cabinet On the workbench ...

Страница 46: ...rd cabinet Use the supplied fixing accessory for installation when needed RSR20 14E can be mounted on the cabinet using the shipped sunk screw and fixing accessories The following figure shows how to install the RSR20 24 on the rack Follow the same method to install the RSR20 14E Brackets Mounting ...

Страница 47: ... of the router Installing the Power Cable and the Grounding Cable Ruijie RSR20 14E series routers support the following AC power supply AC 100 240 VAC 50 Hz to 60 Hz Verify that the power supply meets the requirement The router power cable is composed of three wires You are recommended use a single phase power socket with a natural connector or a multifunctional PC power socket The neutral point o...

Страница 48: ...ce Standard Asynchronous EIA TIA 232 Baud Rate Default 9600 bps Supported Services 1 Command line interface 2 Connection to the character terminal To connect the console port of the router Connect one end of the supplied configuration cable to the console port of the router and the other end to the DB 9 male connector used to configure the router Verify that a Super Terminal is run on the PC Insta...

Страница 49: ...install an SIC slot baffle in time to protect it against dust and ensure ventilation When you remove a line card keep it distant from the passage in the working room to avoid any damage or accident due to bumping during removal Troubleshooting Line Cards Troubleshooting line cards as follows if the router fails to operate after you have installed a line card Check the interface cable of the module...

Страница 50: ...put engine Set the communication parameters 9600 for baud rate eight data bits one stop bit no parity check and no flow control In addition select VT100 as the simulation terminal type 1 Create a new connection 2 Select the serial port to be connected with the router console 3 Set the communication parameters of the serial port 4 Select a terminal emulation type After setting up the configuration ...

Страница 51: ...217728 detected Prepare installation data Load install package file rgos bin OK Installation is in process ATTENTION Do not restart your machine before finish Installation process finished successfully ATTENTION Restart machine operation is permitted now System load main program from install package Executing program launch at 0x00010000 Ruijie General Operating System Software Release Software tm...

Страница 52: ... seeing the information When using the router for the first time it is recommended you set basic parameters using the configuration function Configuring the Router You need to configure a router before using it For more information about router configuration see the related Configuration Guide and Command Reference ...

Страница 53: ...er the router is powered up the terminal will show the startup messages described in the previous chapter if the system is not operational If the system configuration fails the terminal may display no messages or illegible codes If the terminal does not display any messages check Whether the power system is operational Whether the Console cable is properly connected If the problem remains it is pr...

Страница 54: ......

Страница 55: ...raight through cable to connect the converter cable of the asynchronous interface module to the converter This mode applies to SIC 8A Table Connecting the asynchronous interface module to the Modem Device Cable 1 Cable 2 Cable 3 Peer SIC 8A Asynchronous cable with 1 to 8 crystal connectors RJ 45 crystal jack DB25 male converter N A DB25F interface of the Modem Asynchronous cable with 1 to 8 crysta...

Страница 56: ...module to a terminal Device Cable 1 Cable 2 Cable 3 Peer SIC 8A Asynchronous cable with 1 to 8 crystal connectors RJ 45 crystal jack DB25 female converter N A DB25M interface Terminal like a dumb terminal RJ 45 crystal jack DB9 female converter N A DB9M interface Asynchronous cable with 1 to 8 crystal jacks Straight through cable RJ 45 crystal jack DB25 female converter DB25M interface RJ 45 cryst...

Страница 57: ...rter and V 35 Modem V 35 DCE mode V 35 DCE cables Devices working in V 35 DTE mode Back to back mode V 35 DTE V 35 DCE cables Ruijie Networks SIC 1HS NMX 4HSH Connecting the E1 Interface Connecting E1 line card to the Base Band Modem with an E1 cable Connecting a DB9F interface on an E1 CE1 line card to the Base Band Modem 1 Through a non balanced cable 2 Through a balanced cable with crystal conn...

Страница 58: ...AB Asy SCSIDB68 8 RJ45M 1 5m Asynchronous cable 1 to 8 crystal connector V 03260047 000 CAB Asy SCSIDB68 8 RJ45F 1 5m Asynchronous cable 1 to 8 crystal jack V 03260034 000 CAB Rolled RJ45M RJ45M 3m Rollover cable V 03260060 000 ADAPTER RJ45F DB9F RJ 45 crystal jack DB9 female converter V 03260061 000 ADAPTER RJ45F DB25M RJ 45 crystal jack DB25 male converter V 03260062 000 ADAPTER RJ45F DB25F RJ 4...