4C Series Switch Hardware Installation and Reference Guide
Appendix A Connectors and Connection Media
- 41 -
Figure A-1 Four twisted pairs of the 1000BASE-T
In addition to the above cables, the 100BASE-TX can use up to 100m of 100-ohm CAT5. Figure A-2 shows the
definition of pin signal concerning the 100BASE-TX:
Figure A-2 Definition of pin signal concerning the 100BASE-TX
Pin
Socket
Plug
1
Input Receive Data+
Output Transmit Data+
2
Input Receive Data-
Output Transmit Data-
3
Output Transmit Data+
Input Receive Data+
6
Output Transmit Data-
Input Receive Data-
4, 5, 7, 8
Not Used
Not Used
Figure A-3 shows the feasible connections of the straight-through and crossover twisted pairs of the 100BASE-TX.
Figure A-3 Connection of the twisted pairs of the 100BASE-TX/10BASE-T
Fiber Connection
For the fiber ports, select single-mode or multiple-mode fibers for connection according to the fiber module connected.
The connection schematic diagram is shown in Figure A-4:
Figure A-4 Schematic Diagram for Fiber Connection