RG-SS6510
-
4C Series Switch Hardware Installation and Reference Guide
Product Overview
- 14 -
Blinking green
The power is PS off, 12VBS.
The power is in cold backup status and does not
output power.
Solid red
An error occurs, e.g., overcurrent, overvoltage or
fan fault.
The AC power in redundancy is plugged out.
Blinking red
An alarm is generated but the power module
keeps working. The alarm may be caused by
high power, high current, high temperature, or
low fan rotation speed.
Specifications
Model
RG-PA800I-F(AC)
RG-PA800I-F(HVDC)
Rated Voltage
100V AC to 240V AC
50/60 Hz
240V DC
Max Voltage
90V AC to 264V AC
47 Hz to 63 Hz
192V DC to 288V DC
Max Power Output
800 W
800 W
Input
Leakage
Current
≤
1.75 mA
Weight
0.9 kg (1.98 lbs)
Dimension (W x D x
H)
224.94 mm x 73.5 mm x 40 mm (8.86 in. x 2.89 in. x 1.57 in.)
Power Cord
10 A power cord
Please make sure that the power cord has been removed before plugging in or plugging out the power module.