Power Consumption <125W
EMC Standards
GB9254-2008 CLASS A
Safety Standards
GB4943-2011
Operating
Temperature
0 to 50°C
Storage
Temperature
-40 to 70°C
Operating Humidity
10%-90% RH (non-condensing)
MTBF 290,000
hours
Weight
Net weight: 3.80 kg
Dimensions
(W x D x H)
399 mm x 440 mm x 40.18 mm
M18000-48GT-P-ED
Module Appearance
Figure 0-10 Appearance of the M18000-48GT-P-ED Module
External Port
The M18000-48GT-P-ED provides 48 copper ports. The RJ45 ports support auto-negotiation at 10/100/1000 Mbps, and
hot swapping. Copper ports do not support half-duplex at 10/100Mbps.
PoE Power Supply
The M18000-48GT-P-ED supports IEEE802.3af and IEEE802.3at PoE. It adopts the Alternative A mode for transmitting
power over Ethernet cabling, that is, power is transmitted through cable pairs 1, 2, 3 and 6.
LED
LED
Identification on
the panel
Status
Meaning
Off
The module is NOT receiving power.
Solid red
The module is faulty.
Solid yellow
High temperature alarm. The system keeps
operating but the performance is affected
Blinking green
Initialization is in progress. Continuous blinking
indicates errors.
System LED
Status
Solid green
The module is operational
Solid green
Switching mode
Mode LED
Mode_Led
Solid yellow
PoE mode
Off
The port link is NOT connected.
Solid green
The port is connected at 1000Mpbs.
Solid yellow
The port is connected at 10/100Mbps.
RJ45 port LED (in
switching mode)
Link/ACT
Blinking
The port is transmitting and receiving data.
Off
The port does NOT provide PoE power supply.
Solid green
The port provides PoE power supply
RJ45 port LED(in
PoE mode)
Link/ACT
Solid yellow
The port is overloaded and short-circuited,
Power overload causes failure to provide PoE
power supply.
Button
The Mode button has the following functions:
Содержание RG-N18010
Страница 1: ...RG N18000 Series Switches Hardware Installation and Reference Guide V1 08...
Страница 89: ...2 RG N18010...
Страница 92: ...2 RG N18010 bracket installed before delivery Figure 3 13 Installing Bracket to Front Chassis Side...
Страница 121: ......
Страница 133: ...Figures of removing fans for RG N18014 supervisor service and switch fabric modules are similar to figure 7 12...