To secure data and prevent damage to the device, it is recommended to use high-quality SD memory cards
produced by reliable manufacturers. The SD card slot is compatible with most SD memory cards but may be
unable to identify some SD memory cards.
Console port: As a serial communications port, it uses the RS-232 interface level and standard RJ-45 connector.
This port is used to connect the device to serial ports of background terminal computers to perform tasks including
system commissioning, configuration, maintenance, management, and host software loading.
10/100/1000M MGMT port: As the 10/100/1000BASE-T Ethernet port, it uses the RJ-45 connector. This port can be
used to connect the device to the Ethernet port of the background computer to load programs. Use the standard
cable to connect the device to the Ethernet port of the background computer.
Button
The M18014-CM
II
module provides a Reset button, which is used to reset the system. If the button is held for less than
five seconds, it is a short press; if the button is held for five seconds or longer, it is a long press.
In case of a short press, the Status LED flashes in green, and the device resets within five seconds after the
press. In case of a long press, the Status LED flashes in green and then flashes in red; the board resets
within five seconds after the press.
Press the button, and the system starts to collect information, during which the device will not restart. After
the collection is complete, the device restarts automatically. Hold the button for a while and release it, the
device restarts automatically in five seconds.
LED
LED
Identification
on the panel
Status
Meaning
Off
The module is NOT receiving power.
Solid red
The module is faulty.
Blinking green
Initialization is in progress. Continuous blinking indicates
errors.
System LED
Status
Solid green
The module is operational.
Off
The module acts as the standby supervisor module.
Primary/standby supervisor
module LED
Primary
Solid green
The module acts as the primary supervisor module.
Off No
fault
Solid red
The system is faulty, interrupting functioning of the whole
system or a module; the device may be damaged if it
continues operating.
Fault alarm LED
Alarm
Solid yellow
The device overheats, which will affect the system
performance. The system may continue operating.
Off
SD card is not installed, or is not connected.
Solid green
An SD card is loaded.
SD card slot status LED
None
Blinking green Data is being accessed from and written into an SD card.
Off
The module is NOT receiving power or is NOT in the
position.
Solid green
The module is operational.
Solid red
The module is faulty.
FE module status LED
FE
Blinking green
Initialization is in progress. Continuous blinking indicates
errors.
Solid green
The fan is operational.
Fan status LED
FAN
Solid yellow
The fan is NOT in the position.
Содержание RG-N18010