8
Preparing for Installation
Preconfiguring the Access Point (Standalone Only)
Step 2: Supply Power to the CMAP
In this step, you will connect the CMAP to the administrative computer, and then you will
power it on using 12 VDC power.
NOTE:
Before starting this procedure, you must have already obtained a DC power
supply, such as 705-60224-002 shown in
.
To supply DC power to the CMAP
1.
Connect one end of an Ethernet cable to the Ethernet port (labeled
PoE OUT
) on the
CMAP, and then connect the other end to the administrative computer’s Ethernet port.
2.
Remove the protective cap from the DC connector on the CMAP.
3.
Connect the DC adapter (labeled 2 in
) to the DC connector on the CMAP.
Figure 4.
DC switching adapter
identifies the numbered components in
Table 3.
DC switching adapter components
Number
Description
1
Power Supply
: 100 to 240 VAC input. Connects with a standard IEC
C13 style power cord.