Switching LEDs to Cable Modem Mode
Using SNMP to Switch to CM Mode
Figure 21.
The LED Diagnostics page
Using SNMP to Switch to CM Mode
Use SNMP to set MIB values on the CMAP that control the LED mode.
NOTE:
Before starting this procedure, you must first obtain the related MIBs from Ruckus
Wireless. Contact your authorized Ruckus Wireless sales representative or Ruckus Wireless
Support. Visit
http://support.ruckuswireless.com/contacts
for contact
information.
To switch the LEDs to CM Mode using SNMP
1.
Start your MIB browser.
2.
Load the Ruckus Wireless MIBs onto the MIB browser.
3.
In the MIB browser, specify the IP address of the CMAP that you want to configure.
4.
Find the OID
1.3.6.1.4.1.25053.3.1.4.7.3
(ruckusZF7761CMControlLED).
5.
Set the value to one of the following:
•
1
: ledPerCM(1)
– After you set the LEDs to
CM Mode
, they will stay in
CM Mode
until you switch them to another mode.
•
2
: ledPerCMOneHour(2)
– After you set the LEDs to
CM Mode
, they will stay
in CM Mode for one hour, and then they will turn off.
6.
Check the CMAP for a white LED. This indicates that the LEDs are now in
CM Mode
.