RTD Embedded Technologies, Inc.
|
www.rtd.com
52
DMx820 User’s Manual
Field
Description
STOP_TRG[4:0]
Selects the stop trigger. Value definitions are:
31 FIFO1 Interrupt
30 FIFO0 Interrupt
29 Prog. Clock 3 Interrupt
28 Prog. Clock 2 Interrupt
27 Prog. Clock 1 Interrupt
26 Prog. Clock 0 Interrupt
25 PWM1 Interrupt
24 PWM0 Interrupt
23 Reserved
22 Reserved
21 Incremental Encoder 1 Interrupt
20 Incremental Encoder 0 Interrupt
19 Reserved
18 82C54 Interrupt
17 Advanced Interrupt 1 Interrupt
16 Advanced Interrupt 0 Interrupt
15 Inverted Strobe2
14 Inverted Strobe1
13 Strobe2
12 Strobe1
11 Prog. Clock 3
10 Prog. Clock 2
9 Prog. Clock 1
8 Prog. Clock 0
7 82C54 TC B2
6 82C54 TC B1
5 82C54 TC B0
4 82C54 TC A2
3 82C54 TC A1
2 82C54 TC A0
1 Reserved
0 Do Not Stop
PROGCLKn_PERIOD
Sets the period of the programmable clock.
15
0
PERIOD[15:0]
RW,+0
Field
Description
PERIOD[15:0]
The frequency of the output clock is:
)
1
(
_
_
PERIOD
Frequency
Clock
Master
PROGCLKn_COUNT
The current value of the clock counter.
15
0
COUNT[15:0]
RW,+0
Field
Description
COUNT[15:0]
The current value of the clock counter. This starts at a value of
PERIOD, and counts down to 0.