DMx820 User’s Manual
IncEnc1
Interrupt from Incremental Encoder block at 0x02C0
’0’ = Interrupt has not occurred
’1’ = Interrupt has occurred.
Write ‘1’ to clear.
PWM0
Interrupt from Pulse Width Modulator block at 0x0300
’0’ = Interrupt has not occurred
’1’ = Interrupt has occurred.
Write ‘1’ to clear.
PWM1
Interrupt from Pulse Width Modulator block at 0x0340
’0’ = Interrupt has not occurred
’1’ = Interrupt has occurred.
Write ‘1’ to clear.
PClk0
Interrupt from Programmable Clock block at 0x0100
’0’ = Interrupt has not occurred
’1’ = Interrupt has occurred.
Write ‘1’ to clear.
PClk1
Interrupt from Programmable Clock block at 0x0140
’0’ = Interrupt has not occurred
’1’ = Interrupt has occurred.
Write ‘1’ to clear.
PClk2
Interrupt from Programmable Clock block at 0x0180
’0’ = Interrupt has not occurred
’1’ = Interrupt has occurred.
Write ‘1’ to clear.
PClk3
Interrupt from Programmable Clock block at 0x01C0
’0’ = Interrupt has not occurred
’1’ = Interrupt has occurred.
Write ‘1’ to clear.
FIFO0
Interrupt from FIFO block at 0x00C0
’0’ = Interrupt has not occurred
’1’ = Interrupt has occurred.
Write ‘1’ to clear.
FIFO1
Interrupt from FIFO block at 0x00D0
’0’ = Interrupt has not occurred
’1’ = Interrupt has occurred.
Write ‘1’ to clear.
6.3.2
S
TANDARD
I/O
A diagram of the standard I/O is shown in Figure 11. Each digital I/O pin can be an input, output, or peripheral output. The peripheral outputs
are the Pulse Width Modulators, FIFO, Timer/Counters, etc.