71
Dynamics
Dynamics
KEY-IN SELECT popup button
This accesses the KEY-IN SELECT popup where you can select
the key-in signal. For stereo-linked channels, there will be
two (L and R). The channel currently selected as the key-in
signal is shown on the button.
KEY-IN FILTER
fig.KeyinFliterGuide.eps
ON button
This turns the key-in filter on/off.
Filter graph
This indicates the approximate response of the key-in filter.
Filter type select buttons
These buttons select one of the following filter types:
Q knob
This adjusts the filter’s Q in a range of 0.36–16.00.
FREQ knob
This adjusts the frequency in a range of 20 Hz–20.0 kHz.
The function buttons have the following operations:
1.
In the fader module section, press a [SEL] button to select
the desired channel.
2.
In the GATE area of the CHANNEL EDIT section, press
[DISP].
fig.PopGate.eps
The GATE/EXPANDER popup will appear.
BPF (Band-pass filter)
Passes the region at the specified
frequency.
HPF (High-pass filter)
Passes the region higher than the
specified frequency.
LPF (Low-pass filter)
Passes the region below the
specified frequency.
[F1 (OVERVIEW)]
Accesses the GATE/EXPANDER OVERVIEW
popup (p. 73).
[F1 (GATE ON)]
Turns the gate/expander on/off.
[F4 (LIBRARY)
Accesses the GATE/EXP LIBRARY popup (p. 73).
[F5 (PEAK CLEAR)]
Clears the level meter’s peak hold or over
indication.
[F7 (KEY-IN SOLO)]
If you turn this on, you can hear the output
signal of the key-in filter (p. 72).
[F8 (CLOSE)]
Closes the popup.