90
Input/output patchbay
Input/output patchbay
Input patchbay operations
1.
Access the PATCHBAY screen.
fig.ScrPatchIn1608.eps
2.
Press [F1 (INPUT)] to access the INPUT tab.
3.
Press [F3 (REAC A)], [F4 (REAC B)], or [F5 (CONSOLE)] to
select the desired location for the input jack.
4.
Move the cursor to the intersection of the desired
channel and jack, and press [ENTER].
fig.ScrPatchInChgConf.eps
If an input port is already patched to the channel, a message
will ask you to confirm the input patching change.
Press [F8 (ASSIGN)] to change the input patching.
If you press [F7 (CANCEL)], the input patching change will be
cancelled.
If the “PATCHBAY CHANGE” item in the CONFIRMATION section
of User Preference (p. 137) is unselected, no confirmation
message will appear in step 4.
Two input jacks may not be assigned to one input channel.
However, one input jack may be assigned to more than one
input channel.
The input patchbay library lets you store the current input
patchbay settings for later recall.
The INPUT PATCHBAY LIBRARY popup is used to perform input
patchbay library operations.
1.
Access the PATCHBAY screen.
2.
Press [F1 (INPUT)] to access the INPUT tab.
3.
Press [F6 (LIBRARY)] to access the INPUT PATCHBAY
LIBRARY popup.
fig.ScrInPatLibGuide.eps
Library data list
This is a list of library data.
The function buttons have the following operations:
For details on library operations, refer to “Library operations” (p.
37).
Editing the input patching
Using the input patchbay library
[F3 (NAME EDIT)]
Accesses the NAME EDIT popup
[F4 (RECALL)]
Recalls the selected library data.
[F5 (STORE)]
Stores the current settings into the selected
library data.
[F6 (CLEAR)]
Clears the selected library data.
[F7 (LOCK)]
Locks/unlocks the selected library data.
[F8 (CLOSE)]
Closes the popup.
If you attempt to patch a CONSOLE IN that an EXT FX is
using, a caution message such as the following will appear:
fig.ScrInPatchExtFx.eps
Press [F8 (DISABLE)] to disable the corresponding EXT FX and
continue with the patching change.
If you press [F7 (CANCEL)], the patching change will be
cancelled.
1
1
M-300_e.book 90 ページ 2010年4月22日 木曜日 午前8時17分