122
Scene memory
Scene memory
OTHER parameter recall scope buttons
Use these to specify other parameters that will be included
in the scope of recall.
Select the parameters that you want to include in the scope
of recall, and de-select the parameters that you don’t want
to be recalled.
The function buttons have the following operations:
1.
Access the SCENE screen.
2.
Press [F6 (GLOBAL SCOPE)].
fig.ScrRecallSafe.eps
The GLOBAL SCOPE popup will appear.
3.
Use the channel recall scope buttons of [F1 (CH 1–
32
)] to
specify the channel recall scope.
4.
Specify the scope of parameters that will be recalled for
the channels you selected in step 3 using the channel
recall scope buttons.
5.
Use the channel recall scope buttons of [F
2
(AUX/MTX
/
MAIN
)] to specify the channel recall scope.
fig.ScrRecallSafeOut.eps
6.
Specify the scope of parameters that will be recalled for
the channels you selected in step 5 using the channel
recall scope buttons.
7.
Use the DCA/MUTE group recall scope buttons of
[F
3
(OTHER)] to specify the DCA/MUTE groups that will be
recalled.
fig.ScrRecallSafeOther.eps
8.
Use the OTHER parameter recall scope buttons of [F
3
(OTHER)] to specify the other parameters that will be
recalled.
If desired, M-48 memories can be stored simultaneously when a
scene memory is stored on the M-300.
The current memory of each M-48 unit will be stored to the
specified memory number (except for M-48 units whose
MEMORY SAFE function (p. 171) is on).
Scenes stored by this operation are set so that when they are
recalled, the memories of the M-48 units will also be recalled.
1.
Access the SCENE screen.
2.
Select the scene number to use as the destination for the
store operation, and press [F2 (STORE)].
fig.ScrSceneStore2.eps
The SCENE STORE popup will appear.
3.
Verify the scene name shown in the name edit field, and
edit it if desired.
The M-48 memory will be stored with the same name.
4.
In the M-48 MEMORY section, add a check mark to the
STORE button
and specify the memory number
.
fig.ScrM48MemStore_Guide.eps
[F1 (CH 1–32)]
Displays CH1–32 as the channel recall scope
buttons.
[F2 (AUX/MTX/MAIN)]
Displays AUX1–
8
, MTX1–
4
, and MAIN L/R/C as
the channel recall scope buttons.
[F
3
(OTHER)]
Displays the DCA/MUTE group recall scope
buttons and the OTHER parameter recall scope
buttons.
[F8 (CLOSE)]
Closes the popup.
Using the Global Scope function
4
Synchronizing scene memories
with M-48 memories
Synchronizing M-48 store operations
1
2
2
1