Personnel:
n
Trained qualified personnel
Protective equipment:
n
Protective clothing
n
Industrial safety helmet
n
Protective gloves
n
High-vis clothing
Tool:
n
Hand tools
Requirement:
n
The TracFeed
®
SFA has been installed.
Chapter 6 ‘Assembly’ on page 39
1.
Remove the dummy plugs (Fig. 16/3) from the enclosure
2.
Place the sealing underlay from the inside of the enclosure
on the cone of the cable termination (Fig. 16/4).
3.
Secure the cable termination (Fig. 16/4) with the sealing
underlay on top of it to the underside of the enclosure
(Fig. 16/2) using two screws (M10).
The sealing underlay must be between the
enclosure and the cable termination.
4.
Lead the cable into the enclosure from below, through the
protective duct (Fig. 16/5) and the cable termination
5.
To ensure strain relief and sealing, fix the cable in the cable
termination (Fig. 16/4).
6.
Fasten the protective duct (Fig. 16/5) to the cable termination
with the cup point screw (Fig. 16/1).
7.
Seal the unused cable terminations with a dummy plug
Cable entry
Fig. 16: Electrical connection
Assembly
Electrical connection > Connecting the electromechanical remote motor drive
14.09.2022
TracFeed
®
SFA Electromechanical remote motor drive
48
Содержание 3EGF020333
Страница 72: ...Appendix Appendix 14 09 2022 TracFeed SFA Electromechanical remote motor drive 72...
Страница 89: ......