6.
Undo the bolt (Fig. 26/4) and nut (Fig. 26/2) on the lower sec-
tion of the shift linkage.
7.
Remove the lower section of the shift linkage (Fig. 26/1).
ð
The TracFeed
®
SFA is out of operation.
11.2 Disassembly
WARNING!
Risk of injury due to improper disassembly.
Stored residual energy, angular components,
points and corners can cause injuries.
–
Ensure sufficient space before starting work.
–
Handle exposed, sharp-edged components
with care.
–
Ensure orderliness and cleanliness in the work-
place. Loosely stacked or scattered compo-
nents and tools could cause accidents.
–
Disassemble the components properly. Note
that some components are heavy. If necessary,
use lifting equipment.
–
Secure components so that they cannot fall
down or topple over.
–
If in doubt, contact customer service at Rail
Power Systems.
Fig. 26: Removing the connecting
rods
1
Lower section of the shift linkage
2
Nut
3
Locking ring
4
M12 bolt
5
Retaining bolt
6
Adjusting lever
Improper disassembly
Decommissioning, disassembly and disposal
Disassembly
14.09.2022
TracFeed
®
SFA Electromechanical remote motor drive