To attach the TracFeed
®
SFA to a lattice steel mast or flat-frame
mast, you need two retaining brackets of different lengths.
Corresponding retaining brackets are available for
different pole types as accessories from Rail
Power Systems GmbH customer service.
Personnel:
n
Trained qualified personnel
Protective equipment:
n
Protective clothing
n
Industrial safety helmet
n
Protective gloves
n
Safety footwear
n
High-vis clothing
Tool:
n
Hand tools
Requirement:
n
The appropriate retaining brackets have been installed, if
necessary.
Chapter 6.3 ‘Assembly preparation’ on page 40
1.
If it was not already installed in
, mount the shorter retaining bracket
(Fig. 12/2) with M16 fastening bolts to the top of the back of
the TracFeed
®
SFA.
2.
If it was not already installed in
, mount the longer retaining bracket
(Fig. 12/4) with M16 fastening bolts to the bottom of the back
of the TracFeed
®
SFA.
3.
Install the retaining brackets with a distance of 400 mm
4.
Fasten the TracFeed
®
SFA and the retaining brackets to the
corner upright of the overhead contact line with the help of
claws and clamps. Make sure that the upper retaining
bracket is installed horizontally and at a distance of
1 200 mm (Fig. 12/3) to the top edge of the foundation.
Assembly on a pole
Fig. 12: Assembly on a pole
Assembly
Assembly > Assembly on a lattice steel mast or flat-frame mast
14.09.2022
TracFeed
®
SFA Electromechanical remote motor drive
43
Содержание 3EGF020333
Страница 72: ...Appendix Appendix 14 09 2022 TracFeed SFA Electromechanical remote motor drive 72...
Страница 89: ......
Страница 90: ...Rail Power Systems GmbH 2022...