![Roving Networks RN-171 Скачать руководство пользователя страница 60](http://html1.mh-extra.com/html/roving-networks/rn-171/rn-171_user-manual-and-command-reference_1492508060.webp)
WiFly GSX
www.rovingnetworks.com
WiFlyRN171-um 2/23/2011
809 University Avenue
•
Los Gatos, CA 95032
•
Tel (408) 395-6539
~
60
~
Join timer/WPA timer
1000
Replacement char
$ (0x24)
Format
0x00
Password “”
(no
password
enforced)
Sensor
0x00
SYSTEM PARAMETERS
Sleep timer
0
Wake timer
0
Trigger 1
(SENS0
pin
wakes
up
the
device)
Auto connect
0
IOfunc
0 (no alternate functions )
IOmask 0x21F0
Print level
1
(prints enabled)
TIME SERVER PARAMETERS
Enable
0
(disabled)
Server address
129.6.15.28 (fixed to port
123 - SNTP protocol)
Zone
7 (pacific USA time)
UART PARAMETERS
Baudrate 9600
parity
n
(none, this is the only option available)
flow
0
(disabled)
Mode
0
WLAN PARAMETERS
SSID
roving1
Channel
0
(automatic scan )
External antenna
0
(off - use on-board chip antenna)
Join mode
1
(automatically scan and join based on ssid )
Authentication mode
OPEN
Mask
0x1FFF ( all channels )
Rate
12
(24Mbit)
Passphrase
rubygirl
Key number
1
Key
0 0 0 0 0 0 0 0 0 0 0 0 0
17.1.
Restoring Default configuration settings:
From command interface use the
factory RESET
command to restore the defaults. This command
automatically loads default settings, and executes a “save” command.
From hardware, setting PIO9 high on power up arms the factory reset functional and toggling PIO9 five (5)
times there after causes the configuration setting to restored to the factory reset.