RKHH2E-(P)AAV33
ROTEX Domestic Hot Water Heat Pump
2018.8
Installation manual
39
12. Unit Fiche
Descriptions
u.m.
RKHH2E200AAV33
RKHH2E260AAV33
RKHH2E260PAAV33
Declared load profile
L
XL
Water heating energy efficiency class
under average climate conditions
A+
Water heating energy efficiency in %
under average climate conditions
%
123
127
127
Annual electricity consumption in kWh
under average climate conditions
kWh
835
1323
1323
Thermostat temperature settings of the
water heater
°C
55
Sound power level Lwa indoors in dB
dB
53
The water heater is able to work only
during off-peak hours
NO
Any specific precautions that shall be
taken when the water heater is
assembled, installed or
maintained
See manual
Water heating energy efficiency in %
under colder climate conditions
%
94
92
92
Water heating energy efficiency in %
under warmer climate conditions
%
135
129
129
Annual electricity consumption in kWh
under colder climate conditions
kWh
1091
1826
1826
Annual electricity consumption in kWh
under warmer climate conditions
kWh
756
1296
1296
Sound power level Lwa outdoors in dB
dB
52