RKHH2E-(P)AAV33
ROTEX Domestic Hot Water Heat Pump
2018.8
Installation manual
19
6.3 Device mounting and
connection
The device must be installed on a stable, flat floor
surface that is not subject to vibration.
Fig. 6
– Overall dimensions
(
2
6
0
l
v
e
rs
ions)
A
B
C
D
E
F
G
mm
mm
mm
mm
mm
mm
mm
650
2000
600
160
1391
-
1085
H
I
(*1)
J
(*1)
K
L
M
N
mm
mm
mm
mm
mm
mm
mm
-
860
275
70
150
380
195
O
P
mm
mm
337,5
10
(*1)
I
and
J
only for RKHH2E260PAAV33
(
2
0
0
l
v
e
rs
ions)
A
B
C
D
E
F
G
mm
mm
mm
mm
mm
mm
mm
650
1714
600
160
1101
-
795
H
I
J
K
L
M
N
mm
mm
mm
mm
mm
mm
mm
-
-
-
70
150
380
195
O
P
mm
mm
337,5
10
6.4 Water supply connections
Connect the cold water inlet and the outlet pipes to the
appropriate connection points (Fig.7).
The table below provides information about the
connection points.
Pos.
Description
Connection/hole
Cold water inlet pipe
G 1”
Hot water outlet pipe
G 1”
Condensate drain
G ½”
Recirculation pipe
G ¾”
Coil for solar thermal
power
G 1”
1/4
Thermistor immersion
sleeve (only in
models provided
with it)
½”G
Fig. 7
– Water supply connections