12 TROUBLESHOOTING
The following section details common troubleshooting procedures.
•
•
Communication to Controllers/PC, page 54
•
•
•
•
•
NOTE:
Lists of part numbers and their descriptions are located in Ordering Information, page 63.
12.1 Hardware
Connected hardware is not recognized in the hardware profile list under system Menu (voice,
cell modem, Line modem)
Refer to Viewing Device Status, page 38.
The Communicator displays O.K. for an installed device and N/A for a device that is not available.
1. Reset the hardware: Turn the battery switch OFF and unplug the power source.
2. Reconnect the power and switch the battery ON so that the unit rescans the hardware.
3. Open the Communicator and check that the device is installed properly.
4. If still not operating, replace the device.
Battery failure alarm is received
1. Make sure the Communicator is connected to an electric power supply.
2. In ‘
Battery Test’
menu (page 37), check the battery and charger status.
3. Open the Communicator's box and check the battery's wiring (Figure 10, page 46).
4. If the wiring connections are OK, replace the battery pack. (Part number: SP-COMM-BAT).
NOTE:
If you replace the voice card, Ethernet card, line modem or cell modem, perform a Cold Start
after replacing the device (Section
12.2 Communication to Controllers/PC
NOTE:
Refer to Displaying the Controllers, page 28 to display the controller.
Not all units found due to updating primary units
. In other words, the number of controllers is not
identical to the number of controllers entered in the Controllers menu (Identifying the Controllers,
page 14).
1. Make sure the Communicator is connected to an electric power supply.
2. Press
Hot Key 0
(page 28) and check if either some of the controllers are missing (empty
squares), or all of them.
3. Check communication with the missing unit:
o
If the system has a wired connection, refer to Channel/Signal Tests, page 34.
o
If the system has an RF link, refer to page 33.
4. Check Baud Rate (refer to the relevant section in Network Connection, page 26) on both sides
if using 232/485 communication card.