![Rotem P-COMM-V1 Скачать руководство пользователя страница 77](http://html1.mh-extra.com/html/rotem/p-comm-v1/p-comm-v1_user-and-installation-manual_1490994077.webp)
77
Communicator
|
3.05
17 APPENDIX C: COMMUNICATOR / CONTROLLER
CONNECTIVITY
When designing a control system:
•
Rotem Communicator supports multiple infrastructure technologies: RS-232 and RS-485.
•
Each Rotem Controller has its own specific communication card for any supported
communication infrastructure.
•
There is specific wiring required for each infrastructure.
This paper details which 1) controller communication cards to install 2) wiring infrastructure to use in
order to support each infrastructure technology.
Infrastructure
RS-232 Current Loop
RS-485 Standard
RS-485 Isolated
Communicator
Communication
Card
C-COMM-RS232
C-COMM-RS485
C-COMM-485
Controllers' Communication Cards
Platinum
232 ISO / 232 Extension
Card
(P/N: C-PP-RCLP232)
485 ISO/ 232 Extension
Card
(P/N: C-PP-485ISO-232)
232 ISO / 485 Extension
Card
(P/N: C-PP-232ISO-485)
485 STD/ 485 Extension Card
(P/N: C-PP-RCLP485)
485 ISO/ 485 Extension
Card
(P/N: C-PP-485ISO-485)
SuperGuard
N/A
SGP 485 Communication Card
(P/N: C-SG-RCLP)
N/A
Smart 4/8
Smart 232 Communication
Card
(P/N: C-SMART-RS232)
Smart 485 Communication Card
(P/N: C-SMART-RS485)
Smart 485
Communication ISO
(P/N: C-SMART-RS485-
ISO)
AC-2000 3G
Smart 10
AC-3G 232 Comm. Card
(P/N: C-RNET-RS232)
N/A
RLINK 485 Comm. ISO
(P/N: C-RNET-485)
AC-2000 PL/SE
RFS, RSW
Direct On-Board
Use an External RS-485
Converter
Use an External RS-485
Converter
Wiring
3-wire shielded cable
2-wire shielded cable; must be
twisted pair preferred
4-wire shielded cable;
must be twisted pair
Examples
:
•
To connect a Platinum Controller over RS-232 cable, order a Platinum controller equipped with
a 232 ISO / 232 Extension Card or a 232 ISO/ 485 Extension Card. Use 3-wire shielded cable.
•
SuperGuard only supports RS-485 cable. Therefore, order a SGP 485 Communication Card
and use 2-wire shielded cable (twisted pair).