8–2 • Service Information
HDC-8223A(-S) User Manual (Iss. 03)
Troubleshooting Checklist
Routine maintenance to this openGear product is not required. In the event of problems with your
card, the following basic troubleshooting checklist may help identify the source of the problem. If
the frame still does not appear to be working properly after checking all possible causes, please
contact your openGear products distributor, or the Technical Support department at the numbers
listed under the “
Contact Us
” section at the end of the manual.
1.
Visual
Review
— Performing a quick visual check may reveal many problems, such as
connectors not properly seated or loose cables. Check the card, the frame, and any
associated peripheral equipment for signs of trouble.
2.
Power Check
— Check the power indicator LED on the distribution frame front panel
for the presence of power. If the power LED is not illuminated, verify that the power
cable is connected to a power source and that power is available at the power main.
Confirm that the power supplies are fully seated in their slots. If the power LED is still
not illuminated, replace the power supply with one that is verified to work.
3.
Input Signal Status
— Verify that source equipment is operating correctly and that a
valid signal is being supplied.
4.
Output Signal Path
— Verify that destination equipment is operating correctly and
receiving a valid signal.
5.
Card Exchange
— Exchanging a suspect card with a card that is known to be working
correctly is an efficient method for localizing problems to individual cards.