B-5
Appendix B
TABLE B-1. Sizing Guidelines.
To convert flow rate to velocity, use the appropriate factor listed in
Table B-2 and the following equation:
TABLE B-2. Line Size vs.
Conversion Factor.
Application
Velocity Range
(ft/s)
Velocity Range
(m/s)
Normal
Service
2–20
0.6–6.1
Abrasive Slurries
3–10
0.9–3.1
Non-Abrasive Slurries
5–15
1.5–4.6
Velocity =
Flow Rate
Factor
Magmeter Size: 4 inch (factor from Table B-2 = 39.679)
Normal Flow Rate: 300 gpm
Velocity =
300 (gpm)
39.679
Velocity = 7.56 ft/s
Example: English Units
Magmeter Size: 100 mm (factor from Table B-2 = 495.73)
Normal Flow Rate: 800 l/min
Velocity =
800 (l/min)
495.73
Velocity = 1.61 m/s
Example: SI Units
u
Nominal Line Size
Inches (mm)
Gallons Per
Minute Factor
Liters Per
Minute Factor
0.15 (4)
0.055
0.687
0.30 (8)
0.220
2.750
½ (15)
0.947
11.834
1 (25)
2.693
33.657
1½ (40)
6.345
79.297
2 (50)
10.459
130.67
3 (80)
23.042
287.88
4 (100)
39.679
495.73
6 (150)
90.048
1,125.0
8 (200)
155.94
1,948.3
10 (250)
245.78
3,070.7
12 (300)
352.51
4,437.2
14 (350)
421.70
5,268.8
16 (400)
550.80
6,881.5
18 (450)
697.19
8,875.7
20 (500)
866.51
10,826
24 (600)
1,253.2
15,657
30 (750)
2,006.0
25,036
36 (900)
2,935.0
36,670
Содержание 8732C
Страница 1: ...Model 8732C Integral Mount Magnetic Flowmeter System 00809 0100 4725 English Rev BB ...
Страница 2: ......
Страница 4: ......
Страница 10: ...vi ...
Страница 39: ...2 27 Installation ...
Страница 40: ...Rosemount Model 8732C Integral Mount Magnetic Flowmeter System 2 28 ...
Страница 66: ...Rosemount Model 8732C Integral Mount Magnetic Flowmeter System 4 20 ...
Страница 74: ...Rosemount Model 8732C Integral Mount Magnetic Flowmeter System 5 8 ...
Страница 80: ...Rosemount Model 8732C Integral Mount Magnetic Flowmeter System 6 6 ...
Страница 96: ...Rosemount Model 8732C Integral Mount Magnetic Flowmeter System 8 6 ...
Страница 108: ...Rosemount Model 8732C Integral Mount Magnetic Flowmeter System A 12 ...
Страница 116: ...Rosemount Model 8732C Integral Mount Magnetic Flowmeter System B 8 ...