Rosemount Model 8732C Integral Mount Magnetic Flowmeter System
6-2
Software Lockout
Security switch on electronics can be set for deactivation of all LOI
and HART-based communicator functions that affect the transmitter
input/output.
Auxiliary Output Function
In lieu of a scalable frequency output, an auxiliary output is available
using the digital output terminals. Transistor switch closure up to
5.75 W, externally powered, 5 to 24 V ac or dc, to indicate either:
Reverse Flow
Activates switch closure output when reverse flow is detected. The
reverse flow rate is displayed.
Zero Flow
Activates switch closure output when flow goes to 0 ft/s.
Output Testing
Current Source
Transmitter can be commanded to supply a specified current between
3.75 and 23.25 mA.
Frequency Source
Transmitter can be commanded to supply a specified frequency
between 1 and 1000 Hz.
Turn-on Time
30 minutes to rated accuracy from power up; 5 seconds from power interruption.
Start-up Time
0.2 seconds from zero flow.
Low Flow Cutoff
Adjustable between 0.001 and 1 ft/s (0.003 and 0.3 m/s). Below selected
value, output is driven to the zero flow rate signal level.
Humidity Limits
0–100% RH to 150 °F (65 °C).
Overrange Capability
Signal output continues to 110% of upper range value setting, then
remains constant. Out of range message displayed on LOI
and the HART Communicator.
Damping
Adjustable between 0.2 and 256 seconds.
Flowtube Compensation
Rosemount flowtubes are flow-calibrated and assigned a calibration
factor at the factory. The calibration factor is entered into the
transmitter, enabling interchangeability of flowtubes without
calculations or a compromise in accuracy.
Содержание 8732C
Страница 1: ...Model 8732C Integral Mount Magnetic Flowmeter System 00809 0100 4725 English Rev BB ...
Страница 2: ......
Страница 4: ......
Страница 10: ...vi ...
Страница 39: ...2 27 Installation ...
Страница 40: ...Rosemount Model 8732C Integral Mount Magnetic Flowmeter System 2 28 ...
Страница 66: ...Rosemount Model 8732C Integral Mount Magnetic Flowmeter System 4 20 ...
Страница 74: ...Rosemount Model 8732C Integral Mount Magnetic Flowmeter System 5 8 ...
Страница 80: ...Rosemount Model 8732C Integral Mount Magnetic Flowmeter System 6 6 ...
Страница 96: ...Rosemount Model 8732C Integral Mount Magnetic Flowmeter System 8 6 ...
Страница 108: ...Rosemount Model 8732C Integral Mount Magnetic Flowmeter System A 12 ...
Страница 116: ...Rosemount Model 8732C Integral Mount Magnetic Flowmeter System B 8 ...