Galaxy RAID GHDX2-2430S-16U4D Installation and Hardware Reference Manual
5-12
BBU
Installation
•
If a BBU leaks, gives off a bad odor, generates heat, becomes
discolored or deformed, or in any way appears abnormal during
use, recharging or storage, immediately remove it from the
subsystem and stop using it. If this is discovered when you first use
the BBU, return it to your system vendor.
2.8.3 Installation Procedure
To install a BBU into the controller module, please follow these steps:
Step 1.
Prior to installing the BBU, power off the subsystem or restart the
subsystem after the installation. For the power-off process, please
refer to
Section 4.2
.
Step 2.
Remove the BBU slot dummy cover from the chassis
by loosening
the hand screws on the BBU slot dummy cover, then pulling the
dummy cover out of the chassis. (See
Figure 2-7
)
Figure 2-7: Loosening the Dummy Cover Hand Screws
Step 3.
Once the hand screws are loosened, remove the dummy cover from
the chassis. (See
Figure 2-8
)
Figure 2-8: Removing the BBU Slot Dummy Cover