ROPEX CAN
Page 84
RES-5009
Version 1
0006
3 digits (BCD
coded)
Digit 1…3 of the 6-digit device number (e. g. 654
321
)
0007
3 digits (BCD
coded)
Digit 4…6 of the 6-digit device number (e. g.
654
321)
0008
0…40
Current calibration temperature (in °C), channel 0
0009
(
Acknowledgement message (current actual value with reduced controller status)
000A
3…99
Current upper temperature monitoring limit
000B
0…15
(
chap. 11.5,
address 0008)
Current heating band alloy/temperature range
000C
0…65535
Current alarm and Autocal status
(
section 11.6.3 "Alarm /AUTOCAL status" on page 88)
000D
0
1
2
Hold mode: OFF
Hold mode: ON
Hold mode: 2 seconds
000E
0
1
2
AUTOCOMP status: OFF
AUTOCOMP status: ON
AUTOCOMP status: AUTO
000F
0…500
Maximum setpoint
0010
0…999
Software revision
0011
0…99
Software variant (standard value: 00)
0012
400…4000
Current variable temperature coefficient (TCR in ppm/K), channel 0
0013
0
1
2
Temperature OK bit: OFF
Temperature OK bit: active when Setpoint=Actual
Temperature OK bit: active when Setpoint=Actual with latch function
0014
3…99
Lower temperature monitoring limit
0015
3…99
Upper temperature monitoring limit
0016
0
1
Temperature diagnosis: OFF
Temperature diagnosis: ON
0017
0…99
Temperature diagnosis delay in 0.1 s
0018
0…999
Heating time monitoring in 0.1 s
0019
17…30
Measurement impulse length 0.1 ms
001A
0
1
2
3
Temperature range 200 °C
Temperature range 300 °C
Temperature range 400 °C
Temperature range 500 °C
001B
Current device type (RES-5009 = value 33)
Address
(hex)
Value
(dec.)
Meaning
Содержание RESISTRON RES-5009