ROPEX CAN
Version 1
RES-5009
Page 79
0004
37
38
39
40
41
42
43
44
45
46
47
48
49
50
80
81
Query calibration temperature channel 1
Query calibration temperature channel 2
Query calibration temperature channel 3
Query calibration temperature channel 4
Query calibration temperature channel 5
Query calibration temperature channel 6
Query calibration temperature channel 7
Query variable temperature coefficient channel 1 (TCR1 in ppm/K)
Query variable temperature coefficient channel 2 (TCR2 in ppm/K)
Query variable temperature coefficient channel 3 (TCR3 in ppm/K)
Query variable temperature coefficient channel 4 (TCR4 in ppm/K)
Query variable temperature coefficient channel 5 (TCR5 in ppm/K)
Query variable temperature coefficient channel 6 (TCR6 in ppm/K)
Query variable temperature coefficient channel 7 (TCR7 in ppm/K)
Query CAN protocol version
Query active channel
0005
Heating
time and
setpoint
START with specification of heating time and selection of setpoint
Premature “STOP” when heating time = 0
(
section 11.5.2 "START/STOP command" on page 82)
0006
-1, 0…40
Save calibration temperature channel 0 (in °C); -1
variable
0007
3…99
Save temperature monitoring (in K), changes lower and upper temperature moni-
toring limit simultaneously
0008
0
1
2
3
4
5
6
7
10
11
12
13
14
15
Save alloy/range (heating band alloy TCR/temperature range):
TCR = 1100 ppm/K, temperature range max. 200 °C
TCR = 1100 ppm/K, temperature range max. 300 °C
TCR = 1100 ppm/K, temperature range max. 400 °C
TCR = 1100 ppm/K, temperature range max. 500 °C
TCR = 3500 ppm/K, temperature range max. 200 °C
TCR = 3500 ppm/K, temperature range max. 300 °C
TCR = 3500 ppm/K, temperature range max. 400 °C
TCR = 3500 ppm/K, temperature range max. 500 °C
Setting of rotary encoder switch applies (factory setting)
TCR, temperature range, max. setpoint variable (see addresses 000A, 000B, 0014)
TCR = 780 ppm/K, temperature range max. 200 °C
TCR = 780 ppm/K, temperature range max. 300 °C
TCR = 780 ppm/K, temperature range max. 400 °C
TCR = 780 ppm/K, temperature range max. 500 °C
0009
0
1
2
Hold mode OFF
Hold mode: ON
Hold mode: 2 seconds
(
section 9.4.9 "Hold mode" on page 41)
000A
400…4000
variable temperature coefficient (TCR in ppm/K), channel 0
(valid if the value 11
d
was sent under address 0008)
000B
100…500
Maximum setpoint (in °C)
(valid if the value 11
d
was sent under address 0008)
Address
(hex)
Value
(dec.)
Meaning