Mounting and Installation
Version 1
RES-5009
Page 15
7.2
Installation notes
NOTE
The correct dimensioning of the system components is crucial for the correct functioning of the
control loop. Please take this data from the ROPEX application report.
NOTE
In order to enable a good and stable control, additional resistances (fuses, long lines, plug con-
nections, ...) must be avoided in the secondary circuit.
Additional resistances influence the control and can make the system prone to errors, in the
long term.
Line
Impulse
transformer
Current transformer
PEX-W4 / W5
U (prim.)
1
Heatsealing band R= f (T)
U (sec.)
2
A
F
Avoid long
cables
Heatseal element
with coppered ends
Use heatseal bands with
suitable temperature coefficient
20 mm clearance if several
controllers installed on
one top hat rail
No additional
resistance
in secondary
circuit
Dimension
transformer correctly
- Secondary voltage
- Power
- Duty cycle
Sufficient wire
cross-section
No
push-on
connectors
Twisted
Current measuring
wires IR
R
Connect U measuring
wires directly to
heatsealing band ends
Line filter
LF-xxxxx
Note
number
of turns