CANopen
Version 1
RES-5009
Page 61
10.7
Object directory
In addition to the information included in this chapter, further information on the individual CANopen objects can
also be obtained from the EDS file (
section 10.1 "Electronic Data Sheet (EDS)" on page 56).
10.7.1 CANopen standard objects
The RESISTRON
®
Temperature Controller RES-5009 supports the following CANopen standard objects.
The CANopen standard objects are described in more detail in specification CiA 301.
CAUTION
The change of values of the listed objects through write access is temporary. When the device is
restarted, the values must be written again by the CANopen master.
Index
Name
Acc
ess
Standard
value
Range of
values
Data
type
1000
h
Device type
RO
0x00000000
No CAN-
open standard
profile
-
UINT32
1001
h
Error register
RO
-
-
UNIT8
1002
h
Manufacturer status register
(
section 10.7.8 "Manufacturer Status Register
RO
-
-
UINT32
1003
h
Pre-defined error field
SubIndex 0: Number of errors
RW
-
-
UINT8
SubIndex 1...16: Error entries (
RO
-
-
UINT32
1005
h
COB-ID SYNC
Defines the COB-IB for the SYNC message. This
can be changed. Bit 30 must always be 0, as the
RESISTRON
®
Temperature Controller RES-5009
cannot generate a SYNC message.
RW
0x00000080
-
UINT32
1008
h
Manufacturer Device Name (device name)
RO
“RES-5009”
-
STRING
100A
h
Manufacturer software version
Software version of the RESISTRON
®
Tempera-
ture Controller RES-5009, e. g. 5009.00.300
RO
-
-
STRING
1010
h
Store parameters (
restore functionality" on page 71)
SubIndex 1: Save all parameters
RW
0x00000001
-
UINT32
SubIndex 4: Save manufacturer defined parame-
ters
RW
0x00000001
-
UINT32
Содержание RESISTRON RES-5009