ROPEX CAN
Page 78
RES-5009
Version 1
0004
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
256
257
258
259
30
31
32
33
34
35
36
Query setpoint 0 (in °C)
Query setpoint 1 (in °C)
Query setpoint 2 (in °C)
Query setpoint 3 (in °C)
Query the status of the controller
Execute AUTOCAL function
Execute RESET after alarm
Query current actual value
Query device number 1st part
Query device number 2nd part
Query calibration temperature channel 0
Query current value of upper temperature monitoring (see value 22)
Query current value of heating band alloy/temperature range
Query current alarm and Autocal status
Query currently set hold mode
Query current AUTOCOMP status
Query maximum setpoint
Query current software revision
Query current software variant (standard value: 00)
Query variable temperature coefficient channel 0 (TCR in ppm/K)
Query current configuration of temperature OK bit
Query current value of lower temperature monitoring
Query current value of upper temperature monitoring
Query current configuration of temperature diagnosis
Query current value of temperature diagnosis delay (in 0.1 s units)
Query current configuration of heat-up time monitoring (in 0.1 s units)
Query current value of measurement impulse length (in 0.1 ms units)
Query current value of temperature range
Query current device type
preallocate temporary setpoint 0 with stored setpoint 0
preallocate temporary setpoint 1 with stored setpoint 1
preallocate temporary setpoint 2 with stored setpoint 2
preallocate temporary setpoint 3 with stored setpoint 3
Query status of internal clock
Load current system time into temporary memory
Transfer temporary memory to internal clock
Read seconds 'ss' from temporary memory
Read hours 'hh' and minutes 'mm' from temporary memory
Read month 'MM' and day 'DD' from temporary memory
Read year 'YYYY' from temporary memory
Address
(hex)
Value
(dec.)
Meaning