Factory settings
Page 46
UPT-606
10
Factory settings
The CIRUS temperature controller UPT-606 is confi-
gured in the factory as follows:
I
R
signal incorrect
- Up to software revision 015: DIP switches 4 + 5 configured
incorrectly (I
2
range)
- As of software revision 100: I
2
outside permissible range
from 30…500A
Turns through PEX-W2/-W3 cur-
rent transformer incorrect
- Check number of turns (two or more turns required for
currents < 30A)
Internal controller fault
- Hardware fault (replace controller)
- Plug-in jumper for alarm output not connected or incor-
rectly connected
Fault area
Explanation
Possible causes
DIP switches
for
secondary voltage
U
2
and current I
2
(Up to software
revision 015)
U
2
= 6…60VAC
I
2
= 30…100A
DIP switches:2 ON
1, 3, 4, 5 OFF
These switches are automatically set by
the AUTORANGE function on all control-
lers as of software revision 100.
Rotary coding switch
for
sealing element alloy
and
temperature range
heating element alloy: 1700ppm
Temperature range: 300°C
Rotary coding switch: "0" position
Plug-in jumper
for
alarm relay
Alarm relay is energized at alarm
3
2
1
4 5
ON
OFF
SWITCH POS.
1
0
4
5
8
9
300°C
0
5
1 2
3
4
6
7
8
9
0
5
1 2
3
4
6
7
8
9
SWITCH POS.
1
0
4
5
8
9
300°C