Startup and operation
Page 16
UPT-606
8
Startup and operation
8.1
View of the controller
8.2
Controller configuration
The controller must be switched off in order
to configure the coding switches and plug-in
jumpers.
8.2.1
Configuration of the DIP switches
for secondary voltage and current
Automatic configuration (AUTORANGE)
(as of software revision 100)
The secondary voltage and current ranges are auto-
matically configured by the automatic calibration func-
tion (AUTOCAL). The voltage is configured in the range
from 0.4VAC to 120VAC and the current in the range
from 30A to 500A. If the voltage and/or the current is
outside the permissible range, a detailed error mes-
sage appears on the controller (
see section 9.13
"Error messages" on page 40).
Configuration with coding switches
(up to software revision 015)
Set the DIP switches for matching the secondary
voltage U
2
and the secondary current I
2
to the correct
position for
your
application.
You can find the exact configuration of the
DIP switches in the ROPEX Application
Report calculated for your particular application.
Terminals
LEDs
Wiring diagram
Nameplate
Coding switches and
PROFIBUS plug
plug-in jumpers
!
!