Instalattion and operating manual: MGSM 5.0/MGSM 5.0-PS v.1.8S EN
The voice module is capable of replaying the object audio during the alarm or after
establishing the voice message. The module should be connected to the S-M input.
3.2.4 PSR: BUFFERED POWER SUPPLY MODULE
The buffered power supply module 13.8V DC/1.3A with digital MGSM 5.0 communication.
Operation status and failures diagnostics.
3.2.5 PSR-RF: THE BUFFERED POWER SUPPLY MODULE WITH TWO CHANNEL
RADIO CONTROLLER
The extended PSR version with built in two channel radio controller for the remote control of
the MGSM 5.0 (utilizing the control panel function). PSR-RF as an independent device can
functionally replace any two channel radio link and a buffered 13.8V DC/1.3A power supply
(together with the O-R2/O-R3 housings).
4. INSTALLATION
The MGSM 5.0/5.0-PS module should be installed indoors, where air humidity is
normal (RH=90% max. without condensation) and temperature in the range of -10°C to
+45°C. When choosing place of installation the following criteria should be taken into
account:
- GSM network availability (of the SIM card operator utilized in the module),
- the availability and distance of alarm signal sources and trigger signals (e.g. the control
panel),
- the availability of power supplies (e.g. buffered power supply, power supply module etc.) or
installation possibility of such in vicinity,
- the module requires a power supply in the following range:
the
MGSM 5.0 = 10V-14V/1A (min), buffered 13.8V DC power supplies
recommended (e.g. recommended dedicated PSR or PSR-RF)
the MGSM 5.0-PS = 17V-20V/30VA, (the 17V-20V/AC terminals are used for
connection the secondary winding of mains transformer: O-R2, O-R3 casings)
or DC power supplies recommended 20V-30V/1A min (e.g. PSU 24V DC)
- the availability of the premises to third parties and susceptibility to sabotage attempts,
- keeping safe distance from sources of potential interference (e.g. buildings, radio
transmitters, etc. 230V AC main power supply lines).
The MGSM 5.0/5.0-PS module should be mounted in a dedicated metal housing:
- O-R1, O-R2 or other intended for GSM transmitter or control panel installation:
when installing the version without housing,
- information and communication systems via the DIN 35S bus: when installing the version
with housing for the DIN 35S (Z101) bus.
4.1. MODULE COMMISSIONNING PROCEDURE
1. The complete signaling and power supply wiring should be implemented.
2. Mount the housing and insert the wiring through the cable glands.
3. Install the SIM card in the module:
Insert the card in the SIMCARD socket in the vertical position, with the golden contacts of the
SIM card directed towards the closer edge of the PCB board. The marker (cut-out) of the SIM
card must be directed opposite to the direction of inserting.
6