Instalattion and operating manual: MGSM 5.0/MGSM 5.0-PS v.1.8S EN
JI8
is by default (ON)/
NO
in the
software
I8
in the NORMALLY OPEN state, is triggered
by the (short circuit) GND signal.
JI8
is (OFF)/
NO
in the software
I8
in the NORMALLY OPEN state, is triggered
by the disconnecting“plus” signal
●
NC –
denotes the input NORMALLY CLOSED state , triggered by disconnecting „mass”
(0V DC).
The
I7, I8
inputs can be triggered by GND (0V DC) or “plus” (+V
DC
), depending on
the
JI7
and
JI8
settings.
Input in the NORMALLY CLOSED state, triggered by
disconnecting “mass”.
Input in the NORMALLY CLOSED state, triggered by
the (short circuit) “plus” (+U) signal.
JI7 i
s by default (ON)/
NC
in the
software
I7
in the NORMALLY CLOSED state, triggered
by disconnecting “mass”.
JI7
is (OFF)/
NC
in the software
I7
in the NORMALLY CLOSED state, is
triggered by the (short circuit) “plus” signal.
JI8 i
s by default (ON)/
NC
in the
software
I7
in the NORMALLY CLOSED state, triggered
by disconnecting “mass”.
JI8
is (OFF)/
NC
in the software
I7
in the NORMALLY CLOSED state, is
triggered by the (short circuit) “plus” signal.
●
EOL –
denotes the input in the PARAMETRIC state (one parametric resistor), triggered
by
disconnecting the parametric resistor 2.2 kΏ which must be connected
between the input and the system mass.
The input in the PARAMETRIC state is triggered by disconnecting the
parametric 2.2 kΏ resistor.
●
2EOL/NO
– denotes an input in the configuration: two-parametric, NORMALLY OPEN
sensor; the sensor’s circuit is closed with two 1.1 kΩ resistors. 2 EOL inputs enable
the control panel a simultaneous monitoring of sensor status and its sabotage contact.
●
2EOL/NC
– denotes an input in the configuration: two-parametric, NORMALLY
CLOSED sensor; the sensor’s circuit is closed with two 1.1 kΩ resistors. 2 EOL inputs
enable the control panel a simultaneous monitoring of sensor status and its sabotage
contact.
●
OFF –
switches the input off independently of other input settings
Remarks:
•
inputs I1-I8 can be triggered directly by low current OC outputs
•
inputs: I7, I8 can be triggered by positive high current outputs
19
GND
GND
2,2k
+12V
+