Page 02
Introduction
© 2017 Ropam Elektronik
-
visualization and control of alarm system
using input / output, the effect is intuitive control of vigil
by pictograms "arm", "disarm" (expansion and modernization of DSC, Paradox, Satel, etc. by GPRS /
SMS / DTMF control),
- BasicGSM-PS 2 power supply compliant with PN-EN 50131-6, step 1 or 2, power supply type A,
- Operation with PSR-ECO-2012-RS (only BasicGSM 2 modules).
Appliance
BasicGSM 2 / - PS terminals are designed for integration with other devices (eg visualization and control
of the alarm system using the input / output), the effect is intuitive control of vigil by pictograms "arm",
"disarm" (expansion and modernization of DSC, Paradox, Satel, etc. by GPRS / SMS / DTMF, PLC
controllers, relays, drivers) via binary inputs and outputs. With built-in GSM modem it is possible to
transmit events from the system via SMS, VOICE, E-MAIL. For servicing and control serves SMS, CLIP,
DTMF, RopamBasic, RopamDroid.
Appliance:
• notification for alarm systems,
• notification for Fire Brigades TSO with siren control,
• multi-operator control of gate automation, barrier via CLIP (CallerID),
• home automation systems, timer functions,
• systems for monitoring and control via GSM signals, binary I / O,
• temperature control and monitoring systems eg server rooms, refrigerators (vaccines), refrigerators,
thermal processes,
• analogue sensor control and monitoring systems with 0-10 V outputs, 4-20 [mA], eg relative humidity,
temperature,
• temperature control,
• access control systems,
• monitoring and control of technological processes, for example. pumping stations, CO boiler, feedlots,
• Buffer 12VDC power supply (UPS 12V) for additional devices, relays, lights. (versions -PS).
Warrnings
Ropam Elektronik units are part of a complete alarm system, whose effectiveness depends on the
quality and technical condition of all devices (detectors, signalers), wiring, etc. of the system. The user
is required to periodically test the operation of the alarm system. Detailed system control is determined
by the installer who designed the system. Periodic system maintenance (with state control, backup
power, system operation, notification, etc.) is recommended.
Ropam Elektronik is not responsible for the correct operation of operators and GSM network
infrastructure used for alarm and remote control messages. It is advisable to use a GSM operator that
guarantees min. Two BTSs of the given system location with GSM communication. In addition, we
recommend using such services and subscriptions available on the market that guarantee correct
operation (human factor minimization, eg blocked outgoing calls due to lack of funds in the account,
allow for full configuration of the GSM track (for example, disable advertising services).
We do not recommend using national roaming operators!
In addition, it should be noted that the
services guaranteed by GSM operators are voice services
(VOICE)
rather than SMS, so important information should be transmitted via voice calls and the exact
identification of the event takes place in the SMS (eg VOICE + SMS, CLIP + SMS).
Содержание BasicGSM 2
Страница 8: ...Page 04 Introduction 2017 Ropam Elektronik BasicGSM 2 BasicGSM PS 2 BasicGSM D4M 2 BasicGSM D4M PS 2...
Страница 10: ...Page 06 System description 2017 Ropam Elektronik View BasicGSM 2...
Страница 43: ...Page 39 System configuration 2017 Ropam Elektronik Output setting Settings in the LogicProcessor tab...
Страница 53: ...Page 49 System configuration 2017 Ropam Elektronik DelayKeepOn TRG R O OneShot TRG R O TimeOffDelay TRG R O...
Страница 54: ...Page 50 System configuration 2017 Ropam Elektronik Blinker TRG R O MonoBi TRG R O Delay Alter TRG R O...
Страница 78: ...Page 74 System configuration 2017 Ropam Elektronik About the module...