background image

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Nematron Corporation 

 

 

 

 

5840 interface Drive, Suite 100

 

Ann Arbor, Michigan 48103-9515  

 

USA   

 
 
 
 
 
 
Document No. DOC-IPC-003,  
User Manual iPC-Series & nPC300, Rev C Rel. 11-2014 

 

 

i

PC Series & nPC300 

Ultra-Thin Industrial 

Computers w/ i-Processors 

User’s Guide 

 

User’s Guide

 

Summary of Contents for iPC Series

Page 1: ...40 interface Drive Suite 100 Ann Arbor Michigan 48103 9515 USA Document No DOC IPC 003 User Manual iPC Series nPC300 Rev C Rel 11 2014 iPC Series nPC300 Ultra Thin Industrial Computers w i Processors User s Guide User s Guide ...

Page 2: ...e of the Product upon its return to Nematron This warranty does not apply to any Product which has been subjected to misuse abnormal service or handling or which has been altered or modified in design or construction or which has been serviced by anyone other than Nematron The warranty set forth herein is in lieu of and exclusive of all other warranties express or implied Revision Number Descripti...

Page 3: ...eron P4500 1 86 GHz 2 MB Cache 2 Cores 2 Threads o Intel i5 520M 2 4 GHz 3 MB Cache 2 Cores and 4 Threads o Intel i7 620M 2 66 GHz 4 MB Cache 2 Cores and 4 Threads DRAM Options up to 4 GB 80 GB minimum easily removable SATA solid state drive o Larger Solid State SATA drive upgrade options o 500 GB min SATA hybrid hard drive with Solid State Adaptive Memory Cache Option Numerous I O Ports o Two Gig...

Page 4: ...Series Front Panel Comparison The standard front panels are powder coated aluminum The optional Stainless Steel front panel is type 304 and will not contain a logo pocket or logo on the front The window area is clear polycarbonate when ordered without a touchscreen N A on ATEX Zone 2 22 configurations The touchscreen option is heat annealed glass covered by a polyester overlay The polyester overla...

Page 5: ...User Manual iPC Series nPC300 Rev C Rel 11 2014 Page 5 of 27 I O Panel All four versions of the iPC series and the nPC300 have a common Input Output configuration Figure 2 0 shows the base configuration of the iPC Series not N2800 Fanless units With N2800 Fanless Option Only Figure 2 0 iPC Series I O configuration ...

Page 6: ...zed See CPU manual for more detailed instructions and information on the configuration of this port Gigabit Ethernet Two Ethernet ports are provided that are both capable of 10 100 1000 Base T communications USB 2 0 Six ports capable of USB 1 1 and USB 2 0 are provided 2 USB 2 0 and 2 USB 3 0 on ATOM N2800 unit only Input Power Input power whether AC or DC is supplied via a Phoenix connector See C...

Page 7: ...ies nPC300 Rev C Rel 11 2014 Page 7 of 27 TOUCH SCREEN Optional Touch Screen Technology 5 Wire Analog Resistive Interface Internally via USB Resolution 4096 x 4096 Positional Accuracy Maximum Error 0 18 0 19 ePC1900 4 57mm 4 83mm ePC1900 Positional Accuracy Standard Deviation of Error 0 08 2 0 mm Expected Life 35 000 000 Activations ...

Page 8: ...m Cutout Dimensions H x W 9 68 x 12 10 245 9mm x 307 3mm 12 00 x 15 00 305mm x 381mm 13 70 x 16 35 348mm x 415 3mm 14 90 x 17 75 378 5mm x 450 9mm Weight 10 5 lbs 4 76kg 15 0 lbs 6 80kg 19 0 lbs 8 63kg 22 5 lbs 10 22kg Shipping Weight 14 0 lbs 6 35kg 19 5 lbs 8 84kg 23 5 lbs 10 67kg 27 5 lbs 12 49kg Option Weight SS 2 5 lbs 1 13kg 3 5 lbs 1 58kg 3 75 lbs 1 70kg 4 0 lbs 1 81kg The nPC300 is essenti...

Page 9: ... any additional I O or expansion options Any additional I O installed during application can increase this value ENVIROMENTAL Operating Temperature 0 C to 55 C 0 C to 50 C for Enclosed Options Non Operating Temperature 20 C to 60 C Operating Non Operating Humidity 20 to 80 RH non condensing Operating Shock 15g peak acceleration 11msec Non Operating Shock 30g peak acceleration 11msec Operating Vibr...

Page 10: ...an Union ATEX Zone 2 22 Approvals optional configurations Certificate Number DEMKO 14 ATEX 1374X Note Not all variations of the iPC Series and nPC300 are ATEX zone 2 22 certified only those with the appropriate ATEX markings on the label are certified for use in ATEX hazardous locations All ATEX Certified iPC Series nPC300 Models EN 60079 0 2012 A11 2013 EN 60079 15 2010 ATEX Certified iPC Series ...

Page 11: ...G METHODS TEMPERATURE CODE T6 T4A FOR N2800 OPTION NOTE FOR CLASS I DIVISION 2 INSTALLATIONS NP300 UNITS SUITABLE FOR USE IN CLASS I DIVISION 2 GROUPS A B C AND D HAZARDOUS LOCATIONS OR NONHAZARDOUS LOCATIONS ONLY FOR USE ON A FLAT SURFACE OF A TYPE 1 ENCLOSURE WITH PROVISIONS FOR CLASS I DIVISION 2 WIRING METHODS TEMPERATURE CODE T6 T4A FOR N2800 OPTION WARNING EXPLOSION HAZARD SUBSTITUTION OF AN...

Page 12: ...EEN MUST BE WIPED WITH A DAMP CLOTH PRIOR TO USE CONDITIONS FOR SAFE USE IN ATEX ZONE 2 22 INSTALLATIONS IPC SERIES MODELS EQUIPMENT IS NOT INTENDED TO BE USED IN AREAS THAT CAN RESULT IN SEVERE IMPACT TO THE WINDOW WARNING EXPLOSION HAZARD DO NOT DISCONNECT THE USB PORTS UNLESS THE POWER HAS BEEN SWITCHED OFF AND THE AREA IS KNOWN TO BE NON HAZARDOUS ATTENTION RISQUE D EXPLOSION NE PAS BRANCHER O...

Page 13: ...THE SUPPLY TERMINALS TO THE END EQUIPMENT AND 4 ENCLOSURE MUST UTILIZE A TOOL REMOVABLE COVER DOOR OR PANEL INSTALLATION WITHIN AREAS THAT PROVIDE AN EXTERNAL MACRO ENVIRONMENT OF POLLUTION DEGREE 2 OR BETTER FOR THIS INSTALLATION OPTION THE OPEN TYPE IPC SERIES AND NPC300 INDUSTRIAL COMPUTERS SHALL BE INSTALLED WITHIN END EQUIPMENT THAT COMPLIES WITH ALL OF THE FOLLOWING CONDITIONS 1 THE END EQUI...

Page 14: ...S THE ENCLOSURE OF THE END EQUIPMENT SHALL PROVIDE A DEGREE OF PROTECTION NOT LESS THAN IP 64 IN ACCORDANCE WITH IEC EN 60079 31 FOR GROUP IIIA AND IIIB ENVIRONMENTS THE ENCLOSURE OF THE END EQUIPMENT SHALL PROVIDE A DEGREE OF PROTECTION NOT LESS THAN IP 54 IN ACCORDANCE WITH IEC EN 60079 31 NOTE ENCLOSED IPC VERSIONS A LISTED VESA STYLE MOUNT SUITABLE WITH A MINIMUM LOAD RATING OF 40 POUNDS SHALL...

Page 15: ...ir flow from below or above the monitor If possible mount the computer in a vertical orientation The unit is designed to work in environments up to 50 degrees Centigrade ambient temperature inside the enclosure Remember to account for heat dissipated from other equipment that may be installed inside the same enclosure To install the computer make a cutout according to the diagrams below in one of ...

Page 16: ...TEN TO 8 INCH POUNDS COMPRESSABLE NEMA SEALING GASKET 25 THICK MONITOR FRONT BEZEL MAXIMUN ALLOWABLE PANEL THICKNESS CUT AWAY 325 FRONT PANEL OF NEMA ENCLOSURE MOUNTING CLIP WITH 10x32 SCREW Mounting Clip Installation NOTE WHEN INSTALLING THE MOUNTING CLIPS TIGHTEN THE SCREWS TO 8 10 INCH POUNDS MAXIMUM OVERTIGHTENING THE SCREWS WILL RESULT IN A COMPRIMISED NEMA SEAL AND MAY CAUSE TOUCH SCREEN BRE...

Page 17: ... other equipment that may be installed inside the same enclosure Enclosed Unit Installation The enclosed iPC Series products are intended to be stand alone NEMA Type 1 units These are required to be mounted to a VESA style mount with a minimum load rating of 40 pounds A desktop stand wall mount or articulating arms are examples of VESA style mounts that can be utilized These units are vented for a...

Page 18: ...rong input voltage rating When Field Wiring to these terminals the use of 18 AWG or greater 12 AWG maximum copper wire with 60ºC or 60 75ºC wire insulation and the terminal tightening torque of 7 0 lb in 0 79 Nm is required The terminal screws are shown in Top View below Connect the field wiring according to the appropriate voltage in the table below Strip the wire insulation back on each conducto...

Page 19: ...CONECTE O DESCONECTE LOS PUERTOS USB A MENOS QUE LA COMPUTADORA SE ENCUENTRE APAGADA O EL ÁREA SE CONSIDERE NO PELIGROSA WARNUNG EXPLOSIONSGEFAHR USB PORTS NUR ANSCHLIEßEN ODER TRENNEN WENN KEINE SPANNUNG ANLIEGT ODER DER BEREICH NICHT EXPLOSIONGEGEFÄHRDET IST WARNING EXPLOSION HAZARD DO NOT DISCONNECT EQUIPMENT WHILE THE CIRCUIT IS LIVE OR UNLESS THE AREA IS KNOW TO BE FREE OF IGNITABLE CONCENTRA...

Page 20: ... label insert right bottom shell left and top shell lower right Step 2 Insert your pre wired connector with the screws facing up into the bottom shell See manual for cable wiring instructions Step 3 Insert the wire tie from the bottom shell loop around the cable and come back out of the opposite hole in the bottom shell Step 4 Tighten the wire tie around the cable and the bottom shell Step 5 Seat ...

Page 21: ...ematron and is part number PWR AC EN Enclosed ePC Series IEC Power Cable Power Cable Retention Clip Installed I O Cable Management The iPC Series units include retention mechanisms for securing USB and HDMI cable connections USB and HDMI connections are not secure and can easily fall out Use of the brackets is suggested for all applications and is required for any hazardous locations installations...

Page 22: ...able tie to be used for securing cables Care should be taken to provide an adequate radius for any cable being utilized Too tight a radius can damage the conductors When tightening this securing bar care should be taken not to over crush cables this can damage conductors Cable Securing Bar Installed WARNING EXPLOSION HAZARD DO NOT DISCONNECT EQUIPMENT UNLESS THE POWER HAS BEEN SWITCHED OFF OR THE ...

Page 23: ... are four screws on the back of the bracket that hold the drive If the drive is being replaced these screws secure the drive to the plate To reinstall the drive simply insert the bracket with drive attached into the chassis and slide forward Completely push the drive in and secure the thumbscrews before reapplying power to the unit Solid State Drives mount directly to the bracket however a thin pl...

Page 24: ... XP Professional SP3 for Embedded Systems Standard Windows XP operating system disks are no longer available from Microsoft In order to continue shipping Windows XP for Automation applications Nematron had to switch to a different license scheme Windows XP Professional SP3 for Embedded Systems This is not Embedded XP it is simply a different license procedure By switching to this license Nematron ...

Page 25: ...14 Page 25 of 27 Chapter 3 iPC CPU and BIOS Consult the appropriate iPC Series CPU Board User manuals for more detailed specifications of the CPU board and BIOS details This section will concentrate on the features of the iPC Series units that are externally accessible External I O Connections The following figure shows the externally accessible connections ...

Page 26: ...________________________________________________________________ Document No DOC IPC 003 User Manual iPC Series nPC300 Rev C Rel 11 2014 Page 26 of 27 Pinouts With Celeron i5 and i7 Options Pinouts With Intel N2800 Option Only ...

Page 27: ...____________________________________________________________________________________ Document No DOC IPC 003 User Manual iPC Series nPC300 Rev C Rel 11 2014 Page 27 of 27 This page intentionally left blank ...