background image

Page 77 

 

Technical parameters.  

 

 

 

 

 

© 2017 Ropam Elektronik 

7. Technical parameters. 

PARAMETER 

VALUE 

Power supply 

BasicGSM 2, 

U = 10,5V÷14,5V/DC  

min/max @ 1,5A min. 

Power supply

  

BasicGSM-PS 2, 

U = 16V÷20V/AC 

min/max  @ 30VA min. 

U = 20V÷28V/DC 

min/max @ 0,7A min. 

Output voltage of the power supply 

BasicGSM-

PS 2,  

Un= 13,8V/DC (+/- 2%) 

U=10,5V-13,8V/DC**

Power adapter power 

BasicGSM-PS 2,  

(current efficiency)* 

20W  (1,5A) 

DC power failure signaling 

U<11V  

Output load 

O1 

In=1,0A @30VDC/50VAC 

Output load 

AUX 

In=1,0A 

(ciągła)

 

Ipeak=1,3A (chwilowe) 

Short-circuit and thermal output 

AUX

 protection

 

Ilim=1,0A÷1,7A, Tj, Tc= 125  

°

(Status: short-circuit current limitation or output overload) 

Outputs load 

O2-O4 

700mA @30Vdc  

max. 

(no short-circuit protection) 

Current consumption by module circuits 
(without outputs) 

40mA/50mA/300mA 

min/mid/max 

Battery compatible with BasicGSM 2 -PS,

 

12V, 1,2Ah - 12Ah (VRL/SLA) 

Battery charging current 

BasicGSM-PS 2, 

MultiGSM-PS 2 

Ibat= 0,3A max. 

(Charging constant: voltage and current) 

Output protection 

+BAT- BasicGSM 2-PS, 

undervoltage: 

Ubat<10,0V  (+/-5%) 

reverse polarity protection and short-circuit protection:

1.6A PTC 

fuse (reversible) 

Modem GSM 

Quectel M66 (Quad-Band, GPRS class 10) 

detection of jamming GSM 

GSM modem working frequency 

850/ 900/ 1800/ 1900 MHz 

(switched automatically) 

Data transmission type 

SMS, VOICE, GPRS, E-MAIL (protocol SMTP) 

Signal audio AUDIO IN, AUDIO OUT (connector 
VSR) 

2Vrms.  

 
Binary inputs (programmable) 

NO, NC,  

hi-

Z/~200Ω, ~320Ω/hi-Z,  

Line impedance for type: no violation / violation 

 
 

Analog inputs (programmable) I7, I8 

Uin= 

 0-10V/DC (max.) 

(impedance Z=270K

Ώ , resolution 10mV,  

accuracy 1% of the whole range) 

Содержание BasicGSM 2

Страница 1: ...tion and control module GSM terminal Ropam Elektronik Tel 48 12 272 39 71 Faks 48 12 379 34 10 Polanka 301 32 400 My lenice Polska www ropam com pl biuro ropam com pl Wersja dokumentu 1 0 2017 10 06 I...

Страница 2: ...rical and electronic equipment must not be disposed of with household waste According to the WEEE directive EU Directive 2002 96 EC electrical and electronic equipment used should be used separately I...

Страница 3: ...131 6 10 Wiring system 12 Installation and commissioning procedure 12 Connection of devices to the inputs 13 Connecting devices to the outputs 14 Connection of speech synthesizer audio module 16 4 Sys...

Страница 4: ...tion TELEPHONE NUMBERS SMS CENTER 59 Remote configuration TEMPERATURE 59 Remote configuration OTHER SETTINGS 60 Ropam Basic mobile Application 61 Set access to the application 61 Description of applic...

Страница 5: ...S power supply with built in buffer battery support and emergency power supply New terminals are equipped with the latest GSM modem for 2G networks and many new features The basic features of the Basi...

Страница 6: ...temperature temperature control access control systems monitoring and control of technological processes for example pumping stations CO boiler feedlots Buffer 12VDC power supply UPS 12V for addition...

Страница 7: ...system knowledge of SMS code login password for application and active option Possible change of configuration via SMS SMS active control send confirmation of SMS command execution to control outputs...

Страница 8: ...Page 04 Introduction 2017 Ropam Elektronik BasicGSM 2 BasicGSM PS 2 BasicGSM D4M 2 BasicGSM D4M PS 2...

Страница 9: ...Page 05 System description 2017 Ropam Elektronik 2 System description Description of connectors and components...

Страница 10: ...Page 06 System description 2017 Ropam Elektronik View BasicGSM 2...

Страница 11: ...puts 0 7A 24VDC short circuit protection OCP Overload OLP Thermal OHP Overvoltage OVP FAC AC power supply switch DC V supply voltage eg 24V the device must be powered from an AC DC or DC DC power supp...

Страница 12: ...on FAIL RED a series of short flashes approx every 2 seconds TROUBLE CODE including SMS STATE 01 low level of network below 2 bars RSSI 15 02 modem not logged on GSM network 03 failed to send three SM...

Страница 13: ...dio messages 8 x 16sec 8 x 8sec additionally allows to connect audio module for listening to the object Terminal functions allow you to add independent messages from several 5 recordings in case of vi...

Страница 14: ...should be carried out in accordance with applicable standards and regulations When selecting the module mounting location the communication module should be guided by the following criteria GSM netwo...

Страница 15: ...e device delivery as well as transforming and separating electrically electrical power to the I HAS or part thereof comprising at least PU and SD Power Supply Unit PU a device that supplies converts a...

Страница 16: ...t the wiring through the cable glands 3 Install the SIM card in the module the card must not be installed while the power is on insert horizontally into the SIMCARD connector the gold plated SIM card...

Страница 17: ...omputer to the USB Micro jack 10 Configure the system as needed 11 Make tests and tests 12 Disconnect the cable from the USB microphone connector Connection of devices to the inputs The system support...

Страница 18: ...le BasicGSM Manager Input I7 I8 in the configuration NO configurable software BasicGSM Manager Input I7 I8 to connect a voltage or current source FAC input for AC voltage control on isolation transfor...

Страница 19: ...e 12V DC acoustic and or optical Output O1 connection of 12V DC load O2 O4 in the active state can supply NO or disconnect NC 0V power supply GND open collector transistor output OC control supply gro...

Страница 20: ...erature protection return to normal operation if the problem is resolved Connection of speech synthesizer audio module The system is equipped with a VSR socket for connecting VSR 2 speech synthesizer...

Страница 21: ...ject when an alarm or voice call is triggered connection to a module from authorized numbers Use the 5 pin plug to connect the modules The connection should be performed according to the diagram using...

Страница 22: ...of the program toolbar The program has a text graphic menu Unauthorized operations or features for this type of device are displayed as inactive gray icons or captions Communication functions are onl...

Страница 23: ...e communication press the USB icon the yellow LED SEND 4 5 times 11 Disconnect the cable from the micro USB connector 12 Perform tests user training Connection to the module via GPRS The BasicGSM 2 mo...

Страница 24: ...the SIM card and start the module without worrying about locking the SIM card by entering the wrong PIN code by the module no PIN code is required to disable the PIN code request only for non PIN card...

Страница 25: ...ding SMS and dzwonienia module will not turn on GSM modem and thus the system will not appear on the failure of GSM calling sending SMS SMS CENTER The number of the SMS center select on the operator t...

Страница 26: ...vent notifications will be sent to the system The image shows an example of how to set up a Gmail account ACCESS TO THE ROPAMBASIC MOBILE APPLICATION MODULE This option allows you to support BasicGSM...

Страница 27: ...e monitoring station RopamRMS or other using KronosNET protocol The system allows enabling GPRS monitoring with selected ARC monitoring stations or notification via SMTP server by e mail Warning If GP...

Страница 28: ...serve as a filter for SMS and or CLIP control email Numbers should be written in international format Tab Inputs Overview of BasicGSM 2 input settings Input settings binary I1 I6 NAME Name assigned t...

Страница 29: ...es armed the end of the violation turns off or monostable the button when enabled option LINE OF PULSE the action is then the first violation will arm the module the second violation disarms alternate...

Страница 30: ...log you must configure its parameters name easier identification of the measured value Alarm when higher lower than allowed SMS CLIP e mail notification of required content It is also possible to set...

Страница 31: ...Page 27 System configuration 2017 Ropam Elektronik Sample setting of I7 input to which a liquid level sensor with output 4 20 mA is connected Input principle...

Страница 32: ...mRMS or KronosNET monitoring station Audio message To select the available messages recorded in the VSR 2 module or module specify the message number to be played for the event Configure messages in t...

Страница 33: ...d to NC O2 O4 ACTION Mono monostable one stable state the output changes the normal mode after the event marked in the Switched on field for time specified in the Time s after this returns to its norm...

Страница 34: ...iven output via SMS will require to place in the content except SMS ON SMS OFF SMS CODE tab Communication tests counters DTMF On OnIn the tab we enter the DTMF code which will turn on output DTMFOn re...

Страница 35: ...tion is selected then other triggering changes functions of output state are overwritten by the LogicProcessor loop The output operation based on the LP allows to achieve a result based on many of sys...

Страница 36: ...xt of the SMS sent when the output change to state 0 is inactive CALL 0 1 column to activate a voice call CLIP or voice message when you change the output state to 1 active E mail to column to mark th...

Страница 37: ...ge 33 System configuration 2017 Ropam Elektronik Tab Timers Four independent timers for controlling system arming output control LogicProcessor functions Each timer can have 20 independent on off aler...

Страница 38: ...r password to protect the unauthorized reading of data from the module using the computer and the BasicGSM Manager application If the password is incompatible it is not possible to read the settings f...

Страница 39: ...M card installed in the module drop down menu if there is no operator in the list you can enter the command manually set a lower limit not less than 5 PLN that is valid for proper system work Account...

Страница 40: ...tem is supported by the application RopamDroid needed for the visualization of system operations module BasicGSM 2 Optionally disable if you do not use the module control from the RopamDroid applicati...

Страница 41: ...sage from BasicGSM 2 memory Tab Temperature BasicGSM 2 allows you to measure temperature with the digital temperature sensor TSR xx The temperature is measured every 30 seconds The accuracy of the mea...

Страница 42: ...above 32 C COMMENTS The Thermostat control must be based on the functions available in LogicProcessor Temperature sensor failure Notification of failure defect of the temperature sensor sent to the s...

Страница 43: ...Page 39 System configuration 2017 Ropam Elektronik Output setting Settings in the LogicProcessor tab...

Страница 44: ...maximum size of the LogicProcessor script can be 2048 bytes Maximum number of rows 10 comments Available resources logical function for the arguments inputs outputs markers 0 1 binary value temperatu...

Страница 45: ...physical outputs results of functions in LogicProcessor can t be triggered by other events than the LP in the outputs tab bacause they will be overwritten by logic functions All logic and time functio...

Страница 46: ...er on ON OFF 0 timer off OFF ON tla Temperature indicator for threshold L takes binary value 0 or 1 object type Binary Value 1 temp L 0 temp L histereza tha Temperature display for threshold H takes a...

Страница 47: ...object type Binary Value 1 description of result in table Logical function Logical function If Symbol Description Name returns true if both arguments are the same value equality returns true if both...

Страница 48: ...value has n 1 input signals This means that 0 appears only then when all the signals are 1 A1 0 0 1 1 NOR negated logical sum NOT OR A1 A8 this is a logic system that performs the following functions...

Страница 49: ...e function generates the SMS to the indicated numbers as the argument A1 you can give the text and phone numbers in the form 1 2 3 4 5 6 7 8 and A2 argument another system argument eg power function w...

Страница 50: ...is started variable Tk1 1 and the input will be violated I1 1 Variable M1 triggers a time relay PONS for the duration30s Relay as output has indicated O4 gives GND at startup which controls relay wil...

Страница 51: ...Page 47 System configuration 2017 Ropam Elektronik Output setting Listing logic script int I1 int M1 int O4 int tk1 main gbenv while 1 gbenv I1 geti 1 O4 geto 4 M1 tk1 I1 O4 pons 0 M1 0 30 seto 4 O4...

Страница 52: ...s triggers and reset timers blocks identical to arguments in logic functions and results are written to outputs or markers Symbol Parameter Description TRG Trigger triggering signal T Time time of tim...

Страница 53: ...Page 49 System configuration 2017 Ropam Elektronik DelayKeepOn TRG R O OneShot TRG R O TimeOffDelay TRG R O...

Страница 54: ...Page 50 System configuration 2017 Ropam Elektronik Blinker TRG R O MonoBi TRG R O Delay Alter TRG R O...

Страница 55: ...failure Tab Online view The Online View tab allows you to fully control the state of the module and its functions The online preview mode does not disable the full functionality of BasicGSM 2 The syst...

Страница 56: ...view requires active connection via USB or GPRS connection In the ON LINE mode the module performs its standard functions eg sends SMS messages when zones are violated etc CONTROL OF OUTPUT STATE Thi...

Страница 57: ...module AC voltage AC voltage indicator connected to FAC input for BasicGSM 2 works when AC detection enabled connected to the module s power terminals for BasicGSM PS 2 GPRS is none Indicator of pres...

Страница 58: ...ME AND DATE Pressing the SET TIME AND DATE box saves the time and date from the PC to the module The correct time and date is required to send a transmission test according to the clock and correct re...

Страница 59: ...e number number separator of SMS content yyyyyyyyyy sms content max 20 characters for example 48502636033 This is a test message E mail SENDING TEST This feature allows you to send a test e mail direc...

Страница 60: ...tion opens a window where data downloaded from the modem is refreshed They provide advanced GSM network parameters They provide advanced GSM network parameters There are given parameters of the select...

Страница 61: ...able the download wizard will display the missing version information COMMENTS the new version of BasicGSM Manager can also be downloaded manually from www ropam com pl and installed in the same locat...

Страница 62: ...h BasicGSM Manager Module Firmware update Internet connection required current CD included with the latest versions On request we send any archive file for devices that require compliance Updating of...

Страница 63: ...e Error no number added 1111 addphone 48555666888 code SMS nnnn phone number in international format delphone nnnn Removes indicated number from memory After the correct execution module sends the SMS...

Страница 64: ...to current loop mode the setting range is 4 20mA yyyy ai1b Analog input ai1 treshold b setting 1111 ai1b 1500 If the input is set to voltage mode the setting range is 0 10000mV If the input is set to...

Страница 65: ...ion of small data and saves and controls the costs of operating the system The module in continuous connection with the mobile application generates network traffic of about 300MB month RopamBasic con...

Страница 66: ...ntil the connection is established between the user and the module On request of application mobile user after application activation is asked to send an SMS request to set up the connection to the mo...

Страница 67: ...where on the mobile application screen and assign multiple actions to it Icon Description of action Full system armament Possible required code Full system disarming Displays output list Possible set...

Страница 68: ...nsor connected to the system Temperature chart from TSR 1 sensor connected to the system Input view Possible set in BasicGSM Manager input number 1 8 locking the input after pressing the icon after di...

Страница 69: ...o be included Output control of the module 1 4 eg entrance gate Possible set in BasicGSM Manager No of output state indication acc Entry Require code to be included Output control of the module 1 4 eg...

Страница 70: ...le Modular and modem power supply Pre set the application BasicGSM Manager offers the ability to download data from a program and display it in a single application window to facilitate setting and co...

Страница 71: ...GSM Manager and the view of where data is downloaded Description of individual fields in the program User code and TCP IP Password tab Communication tests counters SMS code application log Phone numbe...

Страница 72: ...for controlling your system RopamDroid is supported by smartphones running Android Basic application properties support Android version 2 1 6 clear graphical interface and status bar application and...

Страница 73: ...RopamDroid application description Application main window Description of the buttons and functions of the main window PIKTOGRAM FUNKTION Disarming the module Arming of the module View status of zone...

Страница 74: ...values and analogue AI values and possibility of changing the thresholds A B Hi and Lo Cumulative text of system status button for querying account status setting time and date Request for current sys...

Страница 75: ...vel level 1 4 GPRS coverage available or not GPRS Power status indication basic or battery Standby indication Alarm signaling on the system Failure log on the system Installation and configuration of...

Страница 76: ...M Manager Communication tests counters PartnerGSM Options OptimaGSM Manager System Options Notes In the central OptimaGSM SMS password is the same as user code set in the touch panel working in the sy...

Страница 77: ...Account Status button For this function must be selected in the service program send confirmation F1 user command field for other another SMS command eg MMS request the code will be automatically sent...

Страница 78: ...Page 74 System configuration 2017 Ropam Elektronik About the module...

Страница 79: ...t the device to factory settings To restore the module s factory settings turn off the module power insert the jumper RESET turn on the module power User Interface LED blink quickly 3 times remove the...

Страница 80: ...enance No special maintenance is required During periodical technical inspections check the condition of the screw connections emergency power supply clean the PCB with compressed air The system shoul...

Страница 81: ...rcuit protection Current consumption by module circuits without outputs 40mA 50mA 300mA min mid max Battery compatible with BasicGSM 2 PS 12V 1 2Ah 12Ah VRL SLA Battery charging current BasicGSM PS 2...

Страница 82: ...cy 1 of the whole range Working conditions environmental class II t 10 C 55 C RH 20 90 non condensing Connectors AWG 24 12 trundle Dimensions of the electronics board 68 x 87 x 32 1 mm Waga BasicGSM 2...

Страница 83: ...Page 79 Version history 2017 Ropam Elektronik 8 Version history BasicGSM 2 Date Description 1 0 2017 03 27 first version...

Отзывы: