Page 40
System configuration
© 2017 Ropam Elektronik
Listing logic script:
int O4;
int tha;
main(){
gbenv();
O4=geto(4);
while(1){
gbenv();
O4=geto(4);
O4=tha;
seto(4,O4);
};
};
Tab: LogicProcessor
LogicProcessor:
Advanced logic functions and time-logic functions, such as programmable time relays, the ability to
create free home automation features with GSM control.
The maximum size of the LogicProcessor script can be 2048 bytes.
Maximum number of rows: 10 (comments).
Available resources:
- logical function for the arguments: inputs, outputs, markers (0/1 binary value), temperature
thresholds, thresholds for analog inputs (I7, I8), failures, timers, binary values,
- time-logic functions like programmable time relays, triggers and reset timers (blocks) identical as
arguments in logic functions and results are written to outputs or markers,
- four clock timers (annual format) with 20 entries each to the LogicProcessor time option.