Page 38
System configuration
© 2017 Ropam Elektronik
-
Gradient Alarm:
The module sends a notification of exceeding the specified gradient (change rate)
of the temperature outside the specified value defined in the field .... [° C / min].
- Hysteresis:
Temperature difference for lower and upper switching thresholds.
Example:
if the setpoint a = 30 [ºC] and b = 20 [ºC] and the hysteresis is set to 2 [ºC], the module
switches on when the temperature falls below 18 [ºC] and switches off the heat when the temperature
rises above 32 [° C].
COMMENTS:
The "Thermostat" control must be based on the functions available in "LogicProcessor".
- Temperature sensor failure:
Notification of failure / defect of the temperature sensor sent to the
system user. Possible notification options: Same as for alarms over temperature.
- Memory save value interval:
time period between recording of subsequent temperature values to
event memory in the module. Minimum time: 1 [min], max interval: 1440 [min]
Example in LogicProcessor:
The application allows the module to switch on when the temperature
rises above 28 ° C. It switches
off when the temperature falls below 15 ° C. C.
TSR-xx sensor is connected to T1 input, output O4 controls pump via RM85 relay.
Содержание BasicGSM 2
Страница 8: ...Page 04 Introduction 2017 Ropam Elektronik BasicGSM 2 BasicGSM PS 2 BasicGSM D4M 2 BasicGSM D4M PS 2...
Страница 10: ...Page 06 System description 2017 Ropam Elektronik View BasicGSM 2...
Страница 43: ...Page 39 System configuration 2017 Ropam Elektronik Output setting Settings in the LogicProcessor tab...
Страница 53: ...Page 49 System configuration 2017 Ropam Elektronik DelayKeepOn TRG R O OneShot TRG R O TimeOffDelay TRG R O...
Страница 54: ...Page 50 System configuration 2017 Ropam Elektronik Blinker TRG R O MonoBi TRG R O Delay Alter TRG R O...
Страница 78: ...Page 74 System configuration 2017 Ropam Elektronik About the module...