Page 69
VSB[Scale register address]
VSB is Variable Scale Type B. The real value is the value measured by multiplying it by the variable
scale value, and x0.001. Variable scale value indicates one of the values: 1, 10, 100, 1000.
Real measured value = Measured value x Variable scale value x 0.001
Example)
Address
Attribute
Measurement
Format
Scale
Descriptions
40110
R
Current
UINT16
VSB[40118]
•••
•••
UINT16
•••
40118
R
Current scale
UINT16
If Scale is VSB[40118],
Current A register address [40110] = 302, VSB[40118] = Voltage scale [40118] = 10,
Real Voltage A = 302 x 10 x 0.001= 3.02