Page 35
Demand trend section
Address
Attribute
Measurement
Format
Scale
†
Descriptions
41001
R
Total kW demand trend value1
INT16
VSB[41097]
41002
R
Total kW demand trend value2
INT16
VSB[41097]
•••
•••
INT16
VSB[41097]
•••
41096
R
Total kW demand trend value96
INT16
VSB[41097]
41097
R
Total kW demand trend value Scale
UINT16
41098
Invalid
UINT16
41099
Invalid
UINT16
41100
Invalid
UINT16
†
Refer to
“
Measurement Value Calculation
”
Reset section
Address
Attribute
Measurement
Format
Descriptions
41101
W
kWh Reset
UINT16
0x00FF = kWh Reset
41102
W
kVARh Reset
UINT16
0x00FF = kVARh Reset
41103
W
kVAh Reset
UINT16
0x00FF = kVAh Reset
41104
W
All Demand Reset
UINT16
0x00FF = All Demand Reset
41105
W
All Peak Demand Reset
UINT16
0x00FF = All Peak Demand Reset
41106
W
Max/Min Reset
UINT16
0x00FF = Max/Min Reset
41107
W
Offset Reset only for manufacturers
UINT16
0x00FF = Offset Reset
•••
Invalid
UINT16
•••
41200
Invalid
UINT16
Содержание ACCURA 7500