![RollSeal RS-500 Series Скачать руководство пользователя страница 50](http://html1.mh-extra.com/html/rollseal/rs-500-series/rs-500-series_installation-manual_1483766050.webp)
Page 50
RS-500/600 Series Doors
Part No 4801-5154 Rev 01-2017
34
Egress Strap Removal/Re-Installation
34.1
Removal
1.
Remove the door’s head unit cover
2.
Locate the door controller. Place the door in the JOG mode by holding the Up and Down arrows on
the controller at the same time until you see “JOG” in the controller’s display.
Warning!
Failure to stop the door when nearing the full open or full close position
can cause damage to the door components.
3.
Watch the panel closely while slowly jogging/rolling the curtain up on the drive shaft. Stop the door
when you find the area where the quick-link attaches the long yellow Egress Strap loop to the yellow
strap loop of the triangle panel piece.
4.
Turn off the power switch located on the left side of the controller.
5.
Unscrew the quick-link. Make sure not to drop the counter-weight into the door.
6.
Access the inside area of the cooler/freezer box through the door opening. If the strap is hanging
inside, carefully remove the Egress Strap (top center of door) from the door. Remove the gold cam
buckle.
34.2
Installation
1.
Ensure power has been turned off to the controller.
2.
Un-roll the new yellow Egress Strap with attached gold cam buckle.
3.
From the outside area, locate the roller assembly at the top center of the door where the original strap
came into the curtain area from the inside cooler/freezer area. Use anything with some stiffness
(banding material) and feed the stiff item through the roller and down through the slot located in the
inside cooler/freezer area and tape or tie it to the small loop (not the D-ring) of the yellow strap.
Gently pull it through the hole and roller assembly at the top/center of the door.
4.
Ensure the yellow strap is not twisted. Place the counter-weight onto the yellow strap.
5.
Attach the new strap loop to the yellow strap loop on the triangle panel piece using the quick-link.
6.
Attach the new gold cam buckle to the door frame.
7.
Turn the controller on and return to JOG mode, use the down arrow to lower the door to the floor.
Exit JOG mode by holding the Up and Down arrows on the controller at the same time until you see
“---” in the display of the controller.
8.
Press “Open” button. If the Door is set to automatically close, door will time out and automatically
close (if safety beams are clear). If the Door is set to manually close, press “Close” button and door
should close.
Note: If the door does not lower to the Closed position, see 33.3 Resetting (Closing) The
Door.
Note: If you detect any problems, STOP. Disconnect electrical power. Contact your
distributor for assistance.
9.
Press “Open” (and “Close” if required) several times to insure proper operation.
10.
Re-attach the cover.
!
Содержание RS-500 Series
Страница 31: ...Part No 4801 5154 Rev 01 2017 RS 500 600 Series Doors Page 31 17 5 BEA Receiver ...
Страница 46: ...Page 46 RS 500 600 Series Doors Part No 4801 5154 Rev 01 2017 Curtain Installation ...
Страница 58: ...Page 58 RS 500 600 Series Doors Part No 4801 5154 Rev 01 2017 38 SC 325 Wiring Diagram ...
Страница 62: ...Page 62 RS 500 600 Series Doors Part No 4801 5154 Rev 01 2017 40 5 Wiring BEA Receiver and Brother Motor ...
Страница 67: ...Part No 4801 5154 Rev 01 2017 RS 500 600 Series Doors Page 67 ...
Страница 68: ...Page 68 RS 500 600 Series Doors Part No 4801 5154 Rev 01 2017 ...