![RollSeal RS-500 Series Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/rollseal/rs-500-series/rs-500-series_installation-manual_1483766019.webp)
Part No 4801-5154 Rev 01-2017
RS-500/600 Series Doors
Page 19
13.4
Attachment Points of Door
When sizing the clear opening for attachment of the door, pay close attention to the following guidelines. Door
flanges have pre-drilled holes that serve as mounting points of door.
Flange widths are shown in
Diagram 13A
.
1. Make sure that door assembly is plumb & square.
2. The top unit has a top flange and a bottom flange. Make sure these flanges overlap framing.
3. The vertical members have inner flanges and outer flanges. The inner and outer flanges have pre-drilled
holes that serve as attachment points. Make sure the outer flanges overlap framing.
4. When door is raised in front of clear opening (
Section 13.8, Page 22
), Diagram flanges must be flush
against framing for attachment of screws.
Diagram 13A
Bottom View
Framing Members