![RollSeal RS-500 Series Скачать руководство пользователя страница 29](http://html1.mh-extra.com/html/rollseal/rs-500-series/rs-500-series_installation-manual_1483766029.webp)
Part No 4801-5154 Rev 01-2017
RS-500/600 Series Doors
Page 29
17
Wiring Options to the Manaras Operator Terminal Block
For information on wiring the Manaras Operator, refer to the Manaras Installation and Instruction Manual
provided with the door.
Radio Controls: Consists of a radio receiver unit and remote transmitters. These controls consist of
an RF signal being emitted on a "pulse" basis to a mated receiver tuned to the same "pulse" rate.
Once the receiver accepts the code, a relay is activated closing a set of contacts.
Photo-electric units: Can be used as opening and reversing devices. An infrared light is emitted from
the control to a reflector and back. If, during closing travel of the door, the light beam is broken, the
door will reverse to the fully open position.
Digital Keypad: Consists of a control head which is pedestal mounted. Similar to a telephone touch
pad it allows the selective coding of a four number series. Once the programmed series of numbers is
received in their set order, a relay closes and completes a circuit.
Card Reader: A magnetic-mechanical device which accepts sealed and coded cards. The cards
trigger magnets to rise in the cartridge head, releasing a lock mechanism which allows a deeper
insertion of the card. The card then contacts a switch that closes the circuit.
Key Switch: Momentary contact will open door. Can be wall or post mounted for interior or exterior
use.
NOTE
: Certain accessory devices may require additional power wiring.
17.1
Wiring Switches
To Operate Door:
Depress the “Close” button on the Open/Close/Stop switch. Door curtain will unroll to 'closed' position.
Depress the “Open” button on the Open/Close/Stop switch. Door curtain will open to 'Open' position.
Depress button to open or close door as desired.
Open and close the door a few times to test door operation and remove any wrinkles in the door curtain.
If you detect any problems, STOP. Disconnect electrical power. Contact your distributor for assistance.
17.2
Two (2) Position Switch
Содержание RS-500 Series
Страница 31: ...Part No 4801 5154 Rev 01 2017 RS 500 600 Series Doors Page 31 17 5 BEA Receiver ...
Страница 46: ...Page 46 RS 500 600 Series Doors Part No 4801 5154 Rev 01 2017 Curtain Installation ...
Страница 58: ...Page 58 RS 500 600 Series Doors Part No 4801 5154 Rev 01 2017 38 SC 325 Wiring Diagram ...
Страница 62: ...Page 62 RS 500 600 Series Doors Part No 4801 5154 Rev 01 2017 40 5 Wiring BEA Receiver and Brother Motor ...
Страница 67: ...Part No 4801 5154 Rev 01 2017 RS 500 600 Series Doors Page 67 ...
Страница 68: ...Page 68 RS 500 600 Series Doors Part No 4801 5154 Rev 01 2017 ...