System Settings
SY
System Setting Output
Function: System setting output
Syntax:
stxSY:a,b,c,d,e,f,g,h,i,j,k,l,m,n,o,p,q,r,s,t,u,v,w,x;
(RS-232C, Command format: Type 2)
Syntax:
SY:a,b,c,d,e,f,g,h,i,j,k,l,m,n,o,p,q,r,s,t,u,v,w,x
(Telnet, Command format: Type 2)
a: Card in slot
0 Card in slot A
1 Card in slot B
2 Card in slot C
3 Card in slot D
b: Control Input select
0
Direct
playback
1
Program
playback
2
Binary
playback
3
Terminal
REC
c: Direct playback
0
Normal
playback
1
First-In
playback
2
Last-In
playback
3
Sequence
playback
d: Binary Playback Trigger Settings
Level
0
Off
1
On
e: Binary Playback Trigger
Settings-Edge
0
Off
1
On
f: The Method used for specifying the
phrase (Terminal Recording)
0
Binary
1
1
Binary
2
g: AR-LINK Mode
0
Off
1
Master
2
Slave
h: Dual Mono Mode
0
OFF
1
ON
i: Line Thru
0
Off
1
On
j: Line Thru Volume % (0 - 100)
k: Line Thru Fade Out (0S5 - 59S9)
l: Line Thru Fade In (0S5 - 59S9)
m: Equalizer
0 Off
1 On
n: Equalizer Low Gain dB (-12 - +12)
o: Equalizer Low Frequency
0 200
Hz
1 400
Hz
p: Equalizer High Gain dB (-12 - +12)
q: Equalizer High Frequency
0 3
kHz
1 6
kHz
r: Equalizer Attenuation dB (-12 - 0)
s: Input Volume Thru
0 Off
1 On
t: Busy Out - During Delay Time
0 Off
1 On
u: Busy Out - During Phrase Play
0 Off
1 On
v: Busy Out - During Repeat Interval
0 Off
1 On
w: Display Sleep
0 Off
1 On
x: Display Sleep - Sleep Time
(0M30S - 59M59S)
Note:
refer to 4.2.4 YQ command
AR-3000SD (Ver.1.00) Command Reference - 63